5. Remove the fitting from the filter element
assembly by inserting a 6 mm hex wrench
into the internal hex fitting and turning it
counter clock-wise (left). Numbers 4 and 5
in the previous illustration.
6. Disconnect the input line from the filter
element assembly.
7. Remove the filter element assembly
through the rear opening.
NOTE!
If replacing or cleaning just the
filter element refer to the following
illustration for disassembly.
Filter Element
8. Install the new or cleaned assembly by
reversing these procedures.
9. Turn ON the air supply and check for leaks
before reinstalling the cover.
Optional Single-Stage Filter Element
Replacement
These instructions apply to power supplies
where the optional Single-Stage Filter has been
installed.
The Power Supply shuts down automatically
when the Filter Element becomes completely
saturated. The Filter Element can be removed
from its housing, dried, and reused. Allow 24
hours for Element to dry. Refer to Section 6,
Parts List, for replacement filter element catalog
number.
1. Remove power from power supply.
Manual 0-5395
2. Shut OFF air supply and bleed down
3. Disconnect gas supply hose.
4. Turn the Filter Housing Cover counter-
Optional Single-Stage Filter Element Replacement
5. Remove the Filter Element from the
6. Wipe inside of housing clean, then insert
Art # A-07990
7. Replace Housing on Cover.
8. Reattach gas supply.
Optional Two-Stage Filter Element
Replacement
The Two-Stage Air Filter has two Filter Elements.
When the Filter Elements become dirty the Power
Supply will continue to operate but cut quality
may become unacceptable. Refer to Section 6,
Parts List, for replacement filter element catalog
number.
1. Shut OFF primary input power.
2. Shut OFF air supply and bleed down
SERVICE
ESAB CUTMASTER 60
system before disassembling. Filter to
change Filter Element.
clockwise and remove it. The Filter
Element is located inside the Housing.
Housing
Filter
Element
(Cat. No. 9-7741)
Spring
O-ring
(Cat. No. 9-7743)
Cover
Barbed
Fitting
Housing and set Element aside to dry.
the replacement Filter Element open side
first.
NOTE!
If unit leaks between housing and
cover, inspect the O-ring for cuts or
other damage.
system.
Assembled Filter
Art # A-02476