▶ Use the product only within its specified limits.
▶ Keep the laser aperture clean to avoid measurement errors.
▶ Comply with the national accident prevention regulations.
2.4
Laser classification for Class 2 laser products
The device complies with Laser Class 2 in accordance with IEC 60825-1:2014 /EN 60825-1:2014. These
devices can be used without further protective measures.
CAUTION
Risk of injury! Do not direct the laser beam toward persons.
▶ Never look directly into the source of the laser beam. In the event of direct eye contact, close your eyes
and move your head out of the path of the laser beam.
3
Description
3.1
Product overview
3.2
Intended use
The product described is a laser range meter. It is designed for single measurements and for continuous
measurement of distances.
Distances can be measured relative to all objects with a surface consisting of any normally laser-reflecting
material such as concrete, stone, wood, plastic or paper. The use of prisms or other highly reflective targets
is impermissible and, if attempted, can falsify the results.
The product is approved for use with batteries of type AAA.
3.3
Items supplied
Laser range meter, belt pouch, 2 batteries, quick-start operating instructions, manufacturer's certificate,
safety instructions
Other system products approved for use with this product can be found at your local Hilti Store or online at:
www.hilti.group | USA: www.hilti.com
4

Technical data

Power supply (2 x)
Measuring range
Distance measurement accuracy
IEC 60529 protection class (dustproof and sprayproof)
Operating temperature
Recommended temperature range for transport and storage
Weight in accordance with EPTA procedure 01
*2190182*
1
2190182
Display
@
;
Measure / Continuous measurement but-
ton
Area measurement / Units button
=
ON / Delete / OFF button
%
Display
Battery status indicator
&
Last measured value
(
Units
)
Current measured value
+
Measurement reference
§
PD-S
1.5 V
0.2 m ... 60 m
±1.5 mm
IP 54
−10 ℃ ... 50 ℃
−25 ℃ ... 70 ℃
95 g
English