7. TECHNICAL SPECIFICATIONS

7.1.

TECHNICAL CHARACTERISTICS

Voltage Test
Test Range:
Frequency Range:
Test Current:
Lamp Test
Voltage with new battery:
Field strength 150-170 kHz:
Display:
Continuity Test
Dielectrical Strength:
Test Range:
Test Current:
Display:
7.2.

GENERAL CHARACTERISTICS

Power supply
Internal power supply:
Mechanical characteristics
Dimensions (LxWxH):
Weight (battery included):
Safety standards
Compliance with standard:
Insulation:
Overvoltage category:
Max altitude:
7.3.

ENVIRONMENT

7.3.1. Environmental conditions of use

Reference calibration temperature:
Operating temperature:
Allowable relative humidity:
Storage temperature:
This instrument satisfies the requirements of Low Voltage Directive 2006/95/EEC
7.4.

ACCESSORIES

7.4.1. Standard accessories

• Battery (not fitted)
• User manual
60-250V AC
40-60 Hz
< 200mA
approx. 3kV / 280kHz
approx. 100 µV/m
"Test" LED on and acoustic signal
250V AC/DC
approx. 0-5 MΩ
< 7 µA
"Continuity/Voltage" LED on and acoustic signal
1x9V battery NEDA1604, JIS006P, IEC6F22
255 x 60 x 40mm; 10 x 2 x 1in
approx 170g; 5 ounces
IEC/EN61010-1
double insulation
CAT II 300V
2000m (6562ft)
23 ± 5°C; (73 ± 41°F)
0 ÷ 40°C; (32 ÷ 104°F)
<70%HR
-10 ÷ 50°C; (14÷ 122°F)
(LVD) and of EMC Directive 2004/108/EEC