10.3.18 Wash System Page
The configuration page is only available if the
relevant accessory is present (11.1 Washer, page 50).
From the Wash System menu, it is possible to
configure the device wash system functions.
The virtual keyboard allows you to move the unit. Use
the drop-down menu under the virtual keyboard to
set the speed.
The Wide Zoom and Tele Zoom allow you to control
the viewing angle.
• Go to the Nozzle Position/Save the Nozzle
Position: The unit positions the housing
window according to the saved nozzle position.
If necessary, it is possible to save a new nozzle
position.
Fig. 89
• Wash System Activation: It performs the wash
procedure test.
Fig. 90
• Pump Status: Displays the relay status controlling
the pump. Red indicates that the pump is in
operation. Green indicates that the pump is off.
Fig. 91
MNVCU2_1638_EN
• Wiper-on Delay: Time interval that passes
between the moment the water is supplied and
the moment the wiper is enabled.
• Wash Cycle Duration: Duration of the water
supply by the pump.
• Wiper-off Delay: Duration of the brushing cycle
after water supply has been terminated.
Fig. 92
45