Table 3
Guidance and Manufacturer's Declaration - Electromagnetic Emissions
The model VisiClear™ is intended for use in the electromagnetic environment specified below.
The customer or user of the model VisiClear™ should assure that it is used in such an environment.
Immunity Test
Radiated RF
3 V/m
IEC 61000-4-3
80 MHz to 2.5
GHz
Conducted RF
150 kHz to 80
IEC 61000-4-6
MHz
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structure, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically
with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site
survey should be considered. If the measured field strength in the location in which the Model EVL is used
exceeds the applicable RF compliance level above, the model VisiClear™ should be observed to verify normal
operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or
relocating the model VisiClear™.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Buffalo Filter® VisiClear™ Operator's Manual
IEC 60601
Test Level
Compliance Level Electromagnetic Environment - Guidance
3 V/m
3 Vrms
Portable and mobile RF communications
equipment should be used no closer to any
part of the Model EVL including cables,
than the Recommended separation distance
calculated from the equation applicable to
the frequency of the transmitter.
d = 1.7 √P 80 MHz to 800 MHz
d = 2.3 √P 800 MHz to 2.5 GHz
d = [3.5/V1} √P
Where P is the maximum output power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters,
as determined by an electromagnetic site
survey, should be less than the compliance
level in each frequency range.
Interference may occur in the vicinity of