[30]
Fig. 19 View OUT 1, DSM-48...
7.3.4 View OUT 1 – 6/8 (fig . 19)
[30] Buttons to go to a different view
[31] Controls MIXER to adjust the mixed signal from the input chan-
nels for this output; the level indicators are next to the controls;
the input / indication fields (numeric input fields) are beneath the
controls
[32] Curve diagram of the magnitude frequency response
(description
☞
chapter 7 .3 .3, [14])
[33] Control GAIN to adjust the volume for the respective output; the
level indicator is next to the control; the input/indication field
(numeric input field) is beneath the control (same effect as [8])
[34] Switches ON to activate / deactivate the corresponding filter
[35] List field TYPE to select the filter type
[36] Input / Indication field FREQ for the filter frequency (enter values
in Hz)
[37] Input / Indication field Q / BW for the quality factor/ bandwidth
(click Q or BW to change between quality factor and bandwidth)
[49]
[51]
[52]
[53]
[54]
[55]
[56]
Fig. 20 View X-OVER, DSM-48...
36
[31]
[34]
[35]
[36]
[37]
[39]
[40]
[50]
[32]
[38]
[41]
[38] Input / Indication field GAIN for filter boost / attenuation
[39] High pass filter HPF: input / indication field for the cut-off fre-
quency (enter values in Hz, "Off" < 20 Hz)
[40] High pass filter HPF: list field to select the filter type
[41] Low pass filter LPF: input / indication field for the cut-off frequency
(enter values in Hz, "Off" > 20 kHz)
[42] Low pass filter LPF: list field to select the filter type
[43] Switch MUTE to mute the correspond ing output (same effect
as [11])
[44] Switch INVERT for phase inversion
[45] Button COMPRESSOR to call up the configuration window for
the com pressor of the corresponding output (
[46] Rotary knob DELAY with input / indication field for adjusting the
signal delay of the corresponding output; select the measuring
unit from the list field: time or distance (for automatic calculation
of the sound delay time)
[43]
[44]
[46]
[42]
[57]
[58]
[59]
[60]
[33]
[45]
[47]
[48]
☞
chapter 7 .3 .6)