Dip Switch Settings - Parallel Interface Type
All factory settings for DIP switch on the auto cutter model are set at on.
Switch 1-3 on the tear bar model is set at off, and the others are set at on.
(1) Star mode
Switch
1-1
Command emulation
1-2
Should not be changed (Should be set to on)
1-3
Auto cutter
1-4
Sensor adjustment
1-5
Pin #31 (INIT) reset signal
1-6
Handshaking conditions
(conditions for BUSY)
1-7
Automatic status back function
1-8
Should not be changed (Should be set to on)
(2) ESC/POS mode
Switch
1-1
Command emulation
1-2
Graphic adjustment
1-3
Auto cutter
1-4
Sensor adjustment
1-5
Pin #31 (INIT) reset signal
1-6
Handshaking conditions
(conditions for BUSY)
1-7
Automatic status back function
1-8
Should not be changed (Should be set to on)
Switch
2-1
2-2
2-3
2-4
ON
OFF
DIP-SW 1
Switch 1-1
ON
OFF
Function
Function
DIP-SW 2
Function
Always ON
– 9 –
No. 1
2 3 4 5 6 7 8
DIP-SW1
Command emulation
Star Mode
ESC/POS Mode
ON
Always ON
Valid
Invalid
Valid
Offline or receive
buffer full
Invalid
ON
Always OFF
203 DPI
Valid
Invalid
Valid
Offline or receive
buffer full
Invalid
ON
Should be set to on
ON
OFF
No. 1
DIP-SW2
OFF
Invalid
Valid
Invalid
Receive buffer full
Valid
OFF
180 DPI
Invalid
Valid
Invalid
Receive buffer full
Valid
OFF
2 3 4

Werbung

Inhaltsverzeichnis
loading