9. TECHNICAL DATA

In line with Decree No. 2/1984 (III.10.) BkM-IpM, it is certified that our appliances conform
to the following technical specifications.
QUALITY CERTIFICATE
Use
Placement
Volume [L]
Voltage [V]
Heating power [W]
Current input [A]
Heat-up time [h]
Voltage [V]
Heating power [W]
Current input [A]
Heat-up time [h]
Standby energy consumption at 65ºC [kWh/24h]
Water connection
Nominal operating pressure [MPa]
Safety valve highest opening pressure (MPa)
Integrated safety and regulator elements
Other protection
Protection grade
Contact protection rating
Main regulations applicable to the product
Storage and transport requirements
Z150S ErP Z200S ErP
3-phase wiring:
1-phase wiring:
Closed system hot water storage
Floor standing
150
200
400V~3
3x800
3x800
3x4
3x4
4
5.3
230V
2400
2400
11
11
4
5.3
1.3
1.45
G3/4
0.6
0.7
continuously manual adjustable
outlet temperature – regulator,
limiter, combined safety valve
Corrosion protection with active
IP X4
I.
MSZ EN 60335-1,
MSZ EN 60335-2-21
MSZ EN 60721-3
14
Z300S ErP
300
3x1066
3x5
6
3200
14
6
1.93

Werbung