INSTALLATION

only intended for qualified personnel
Before installing the hood, carefully read the chapter 'SAFETY
INSTRUCTIONS AND WARNINGS' .
TECHNICAL FEATURES
The technical specifications are exhibited on the labels located inside the hood.
POSITIONING
Do not install the hood outdoors and do not expose it to outdoor environment
(rain, wind, etc.).
COOKER
ELECTRICAL CONNECTION
(only intended for qualified personnel)
Disconnect the equipment from mains power network before car-
rying out any operation on the cooker.
Make sure that electric wires inside the cooker are not disconnect-
ed or cut:
in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law
in force.
Before connecting the cooker to the mains power network, check that:
the mains voltage corresponds with the voltage indicated on the data
plate located inside the cooker;
the electrical system is compliant and can withstand the load (see the
technical specifications located inside the cooker);
the power supply plug and cable do not come into contact with temper-
atures exceeding 70 °C;
the power supply system is effectively and properly connected to earth in
compliance with regulations in force.
the socket used to connect the cooker is within reach.
In case of:
devices fitted with cables without a plug: the type of plug to use is a
''standardised'' one. The wires must be connected as follows: yellow-green
for earthing, blue for neutral and brown for the phase. The plug must be
connected to an adequate safety socket.
fixed equipment not provided with a power supply cable and plug, or any
other device that ensures disconnection from the electrical mains, with an
opening gap of the contacts that enables total disconnection in overvolt-
age category III conditions.
Said disconnection devices must be provided in the mains power
supply in compliance with installation regulations.
The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety
regulations.
SAFETY DEVICES ON THE COOKER
Safety shutdown
If a cooking area exceeds the maximum time for operation at the same pow-
er, it is automatically switched off and the indication of the residual heat is
shown.
To reset the cooking area, touch the necessary keys.
low
1
2
Power level
Maximum
duration of
8.7 2.0
8.7
operation in
hours
The cooker switches off automatically if one or more controls stay covered for
more than 10 seconds.
To restore the proper operation:
- remove all objects from the control panel.
- clean the control panel.
- restart the cooker and the concerned area.
3
4
5
6
7
8
6.7
5.3
4.3
3.5
2.8
2.3
Overheating device
Before items of the cooker can overheat, the control reduces the used power
by following this procedure for protection measures:
- Deactivation of booster and power booster if turned on.
- Reduction of the power level set.
- Shutdown of the cooking area concerned.
On the display of the cooking area the message "E2" is displayed.
It is possible to restore the cooking area when the default message is of
SAFETY INSTRUCTIONS
FOR ASSEMBLY
Install the cooker after installing kitchen cabinets and basis.
Make sure that worktops have been veneered with thermoresistant glue in
order not to suffer deflections or detachments.
It is forbidden to install the appliance on fridges or freezers, washing ma-
chines, dishwashers, or tumble driers.
Connection of the cooker
network
Connection
220V - 240V~
50/60Hz
380V - 415V~
50/60Hz
380V - 415V~
50/60Hz
* calculated with the contemporary factor in compliance with EN 60 335-2-6.
POWER
:
Feature
Total power
Position 1
Rated power
Booster power
Position 2
Rated power
Booster power (1/2)
9
P
Position 3
Rated power
1.9
1.5
Booster power (1/2)
Position 4
Rated power
Booster power
18
Cable sec-
Power
tion
cable
H 05 VV - F
1P+N / 2P
3 x 2.5 mm²
H 05 RR - F
H 05 VV - F
2P+N
4 x 1.5 mm²
H 05 RR - F
H 05 VV - F
3P+N
5 x 1.5 mm²
H 05 RR - F
2
3
1
4
2800-7400W
f.
Switch
gauge
25 A *
16 A *
16 A *
1600W
1850W
2100W
3000W
2100W
3000W
1600W
1850W