How to fix the sets of inserts on the press
Putting the sets of inserts in place is a simple and fast operation.
Open the head by raising the mobile part (3).
The mobile lower part (4) goes down automatically.
Caution:
The mobile lower part (4) goes down rapidly; make sure your fingers are not caught.
Slide the set of inserts in the notches (5).
A spring-ball enables the insert to be locked into position.
How to remove sets of inserts
Open the head by raising the mobile part (3) of the head.
The mobile lower part (4) goes down automatically.
Caution:
The mobile lower part (4) goes down rapidly; make sure your fingers are not caught.
Push the inserts out of the notches (5).
Using the Viper I10 pressing press
How to choose the appropriate inserts
See section "inserts/profiles".
How to undertake pressing with the Viper I10 press
Positioning of the connection
Select the set of inserts.
Fix the inserts on the pressing press. See the section "How to fix the set of inserts" .
Select the connection suited to the tube for pressing.
Insert the connection on the tube.
Inserting the connection in the clamp and pressing
Open the clamp by raising the mobile part (3).
Slide the connection for pressing on the profile of the clamp while keeping the clamp open.
Check that the connection is positioned at the right place on the profile.
Close the head.
Pump using the advancing trigger (7).
After a few pump actions the press clicks; this indicates the end of pressing.
Press the return trigger (6).
Removing the clamp connection
Open the head by raising the upper mobile part (3).
Remove the clamp from the connection.
Maintenance
Maintaining the inserts
Regularly check that the inserts are in good condition.
Clean the inserts using a dry rag or a metal brush.
12