STOPPING THE CLEANER
1) Switch off the burner by
turning the pressure regulator
to pos. "0" (fig. 7B).
2) Let the cleaner run with
cold water only for at least
30 seconds to cool down the
boiler.
3) After using with detergent,
flush out the intake circuit;
place the detergent suction
hose (fig. 9) in a tank of clean
water and let the pump run for
1 minute with the dosing tap
turned fully on.
Repeat the operation with
the detergent selector set
first to position 1 and then to
position 2.
4) Stop the cleaner by turning
the selector switch to pos. "0"
(fig. 7A).
5) Discharge the pressure
from the H.P. hose by pressing
the trigger on the gun (fig. 6).
6)
Disconnect the water clea-
ner from the mains electricity
supply via the omnipolar
switch or by unplugging the
plug from the socket.
7) Turn off the water supply
tap (fig. 5A).
USE OF THE DOUBLE LAN-
CE (fig. 10)
The double lance allows the
operator to select a low or high
pressure jet. The pressure is
selected with the gun in pos.
1. High pressure: pos. 2. Low
pressure pos. 3.
!
Warning
- If the water cleaner is left,
even temporarily, turn it off by
using the omnipolar switch or
by unplugging the plug from
the socket.
- Water cleaners with the
"Total Stop" device should
be considered as off when
the omnipolar switch is in
the "O" position or the plug
is unplugged from the sock-
et.
- When the water cleaner is not
used, close the safety device
on the handle.(fig.11)
- Dry use of the water cleaner
English
causes serious damage to
pump gaskets.

USING STEAM

Use the steam nozzle (sup-
plied as an accessory).
Turn the thermostat knob
"B" (fig. 7) to steam position
to obtain an increase in the
temperature of the water at
delivery (140°C - 284°F).
FIG. 9
Turn the steam tap anti-clock-
wise to open the steam.
At work temperatures higher
than 95°C (203°F), the work
pressure must be < 32 bar
(460 PSI).
Danger
!
During use with boiling water, "Steam Phase", keep away
from the openings for fumes discharge (risk of burning).
When you have finished using the "Steam Phase", turn
the thermostat knob "B" to position "0" (fig. 7) and let
the machine cool down for about 3 minutes with the gun
turned on.
Turn the steam tap clockwise again to shut off the steam.
FIG. 10
FIG.11