Herunterladen Inhalt Inhalt Diese Seite drucken

Important Notes; Maintenance - Riello N10 Montage- Und Bedienungsanleitung

Heizölbrenner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IMPORTANT NOTES

MAINTENANCE

– The filter on the pre-heater should be periodically cleaned (13, fig. 1); if it is blocked, the pressure
read on the pressure gauge is lower (10, fig. 1).
– The pump also has a large-mesh filter (0.5 mm), therefore frequent cleaning is not required.
– Empty any water inside the pre-heater tank from the outlet valve (16, fig. 1).
– Clean the photoresistance
– Clean the ignition electrodes
– Clean the turbulator diffuser disc.
REPLACING THE REGULATION THERMOSTAT
This is done by unthreading the old probe from the
hole in the tank, and inserting the new one in the
same hole (see the figure alongside).
NOTE
When the burner is running at an output above 9 kg/h,
remove the panel fitted inside the cover (see the figure
alongside).
1440
1441
Thermostat
probe
SONDA TERMOSTATO
7
7
GB
GB
Tank
SERBATOIO
D8382
PANEL
D5861

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

611m

Inhaltsverzeichnis