5.3 No water fault and retries.
In Filtration Plus mode, the system is regularly moni-
tored to check that the pump is not operating without
water.
If SilenPlus detects the pump is working without water
it stops the motor.
The system will attempt to start up again after 1', 5',
15' and 1 hour (Fig. 4). If the retries fail, Evopool will
remain in permanent fault mode.
An LED sequence indicates the fault status. (See fig-
ure 7)
To interrupt the retry cycle or to restart from perma-
nent fault mode, press the F key.
5.4 System status
Espa offers installers and users the EspaEvopool ap-
plication for monitoring the system status and
interacting with SilenPlus.
They must have a Smartphone with Bluetooth
connectivity
and
EspaEvopool available in
PlayStore or AppStore.
With this app, it is possible to switch between Manu-
al/Remote modes and use all functions.
Filterwatch FUNCTION
6.
6.1 Activation.
Filterwatch should only be activated after carrying out
the initial maintenance work, making sure that the filter
is completely clean.
To activate Filterwatch:
- Press "M" for 5 seconds.
- The "Filtration Plus" LED will blink 3 times.
When it is activated, Filterwatch will begin a 3 minute
learning period during which the pump will operate at
100%. Do not interrupt this process.
The correct activation of the Filterwatch function is
indicated by the Filtration Plus LED blinking slowly.
6.2 Auto-adaptation.
With Filterwatch activated, the pump operation during
Filtration Plus
the
phase will adjust itself to the degree
of clogging of the filter.
It is normal to note a gradual increase in the rotational
speed of the pump.
6.3 Filter saturation warning.
When the system detects that it has reached its satu-
ration level, the pump will request that a filter cleaning
cycle be run.
- The Backwash Plus LED will blink quickly.
- If you have the EspaEvopool application, you will re-
ceive the corresponding warning when the pump is
connected.
After cleaning the filter, the warnings will disappear
and the system will return to its normal status.
install
the
application
www.espa.com
and in
6.3 Deactivation.
To deactivate Filterwatch:
- Press "M" for 5 seconds.
- The "Filtration Plus" LED will blink 3 times.
The Filterwatch function will be deactivated and the
Filtration Plus LED will stop blinking.
6.4 System control.
You can activate and deactivate Filterwatch and
control the system status through the EspaEvopool
application.
7. ADVANCED CONFIGURATION
Different speeds can be set to adjust the functions to
the characteristics of the installation.
The function being run will be configured.
To configure a function, first select it, either in Manual
or Remote mode, and at the same time press M + F
for 5 seconds.
All the speeds of the selected function will return to
the factory settings [= fs]
To increase or decrease the speed, press M or F:
M = + 1 Hz
F = - 1 Hz
• Configuring Filtration Plus.
The filtration speed is set.
· Minimum = 20 Hz (1,600 RPM), [= fs]
· Maximum = 50 Hz (2,900 RPM)]
• Configuring Backwash Plus.
The maximum and minimum speeds are set, al-
ways maintaining a differential of 20 Hz between
them
· Minimum = 20/40 Hz (1,600/2,320 RPM), [= fs]
· Maximum = 30/50 Hz (1,740/2,900 RPM)
• Configuring the Mixed Cycle (Manual only)
The factory setting is 2,320 RPM (40 Hz)
· Minimum = 20 Hz (1,600 RPM)
· Maximum = (50 Hz (2,900 RPM)
If M and F are not pressed for 5 seconds the new val-
ues are stored and the configuration mode is
deactivated.
SilenPlus can also be entirely configured using
the EspaEvopool application.
12
EN