7.
Maintenance
!
Do not use abrasive detergents, solvents (petrol,
diesel, etc.) and rough workshop rags to clean the
station. Clean only with a soft cloth and a neutral
detergent.
i
In case of refrigerant leaks during normal use of the
machine and during installation, maintenance or
repair of the machine, no refund will be made by the
manufacturer.
CAUTION: disconnect the power supply
before any maintenance operation.
7.1
Maintenance program
WARNING: to prevent accidents, only
qualified personnel must perform
inspections and repairs on the station. Read
and follow the instructions and warnings in
this manual. Wear protective clothing that
include safety glasses and gloves.
Maintenance operation
Recommended interval
Filter replacement
The filter must be replaced after
150 kg (331 lb) of refrigerant
has been filtered. See Filter
Maintenance in the Maintenance
section of this manual.
Vacuum pump oil change When the filter is replaced or every
100 hours. See vacuum pump oil
change in the Maintenance section
of this manual.
Checking the correct
Every month.
operation of wheels and
rollers
Checking the internal
Every month. See Checking the
scale calibration
calibration in the Maintenance
section of this manual. Every year,
all scales must be calibrated by an
authorized Bosch service center.
Setting to zero of the oil
Whenever necessary. See Scale
drain scale
Reset in the Maintenance section of
this manual.
Leak check
Automatic every 10 days. See Leak
Check in the Maintenance section of
this manual
Cleaning the air suction
Every month. Use a clean cloth.
panels
Cleaning the panel and
Every month. Use a clean cloth.
control panel
Inspection of the
Everyday.
integrity of the power
cable and hoses
Lubrication of wheel
Every month.
bearings and inspection
of brake components
Inspection of solenoid
Every year - performed by an
valves
authorized Bosch service center.
Robert Bosch GmbH
Maintenance | ACS 663 | 69
Maintenance operation
Recommended interval
Internal refrigerant
Everyday.
identifier filter check
(optional, standard on RI
variants)
Filter change and internal
Every six months or whenever it
refrigerant identifier
is dirty and/or clogged. Replace
pick-up hose (optional,
the pick-up hose every the filter is
standard on RI variants)
replaced. See internal refrigerant
identifier maintenance in the
Maintenance section of this manual.
7.2
Spare parts
CAUTION: to prevent accidents, for repairs
use only the components included in
the spare parts list as these have been
carefully tested and selected by Bosch.
Replacement component
Filter
Oil drain bottle
PAG oil injection bottle
POE oil injection bottle
UV dye bottle
Printer paper (only for variants with printer) SP00100087
Low pressure service connection
High pressure service connection
Service hose (low pressure, blue)
Service hose (high pressure, red)
Tank Adapter (1234 <22 HW) + Gaskets
Tank Adapter (1234 DNT) + Gaskets
Vacuum pump oil (600 ml)
Refrigerant identifier filter
(optional, standard on RI variants)
Refrigerant identifier pick-up hose
(optional, standard on RI variants)
en
Code
SP01100355
SP00101727
SP00101914
SP00101913
SP00101915
SP01100525
SP01100524
SP00101644
SP00101643
SP01100352
SP01100353
SP00100086
SP00101646
SP00101645
|
SP00D00616
2019-07-02