en
50 | ACS 663 | Introduction
3.6.2
Settings Menu
Function
Description
Select Language
Select a language from the displayed
ones. The default language is English.
Select Units
To program the machine to display metric
or imperial values. The default view is in
metric system.
Date and Time
To program the current time and date in
the station.
Edit Print Header
Programs the information that appears
in the print summary every time the print
function is used.
Unit Activation
Failure to register and activate the
machine within 30 days of initial start-
up causes the machine to lock and the
impossibility to use it. Select this item
in the Settings Menu and follow the
instructions that appear on the screen
before the trial period expires.
Oil Load Cells
To enable or disable the operation of the
exhausted oil scale.
Dye injection adjust To double or halve the default amount
(about 7.5 ml) of UV dye.
To enable or disable the purity test of the
Refrigerant
external refrigerant identifier connected
Identifier
(only if enabled)
to the USB port of the station. The
display shows three selection options:
+ Always Display Identifier Prompts:
displays the steps required to perform
the purity test.
+ Skip Display Identifier Prompts: does
not display the operations to perform
the purity test.
+ Ask User to connect Identifier: asks
the user, with a message, to confirm
whether or not to perform the purity
test.
Default Vacuum
To change the vacuum time for the leak
Leak Test Time
test.
Set Buzzer
To enable or disable the acoustic signal.
Firmware Update
To upgrade the firmware through a USB
stick or WiFi (with Bosch WiFi dongle
- optional -). The display shows three
selection options:
+ Check for Update: to check if new
firmware updates are available.
+ USB Update: to upgrade the firmware
through a USB stick.
+ Wi-Fi Update: to upgrade the firmware
through WiFi network. If the station
is connected to the WiFi network and
the WiFi network is connected to the
Internet, the search for new updates
will automatically start.
WiFi Configuration
To configure the WiFi connection on the
station.The display shows five selection
options:
+ Search WiFi Networks: to search for
available WiFi networks.
+ WiFi Status: to display some data
related to the WiFi connection used.
+ Test WiFi connection: to perform
a connection test on the wireless
network used by the station.
+ Disconnect current network: to
disable the WiFi network connection
stored on the station.
+ Manual connect: to perform manual
scan and selection of WiFi network.
|
SP00D00616
2019-07-02
Function
Description
Asanetwork
To activate or deactivate the Asanetwork
function.
Information can be obtained from the
service department.
Connected Repair
To activate or deactivate the CoRe
[CoRe]
function. See Connected Repair [CoRe] in
the Initial Settings section.
Default N2 Leak
To change the N2 test time for the leak
Test Time (only if
test.
enabled)
Select
to return to the Setup Menu.
3.6.3
Maintenance Menu
Function
Description
Filter Maintenance
The filter removes acids, particles and
condensate from the refrigerant. To meet
the requirements, it is mandatory to
replace the filter after 150 kg (331 lb) of
refrigerant has been filtered.
This menu item displays the remaining
capacity of the filter before the station is
stopped and stops operating. See Filter
Maintenance in the Maintenance section.
Pump Maintenance
This menu item displays the remaining
time until the next oil change of the
vacuum pump. To obtain the best
performance from the vacuum pump,
replace the oil every time the filter is
replaced. See Vacuum pump oil change in
the Maintenance section.
ISV Purge condition Displays the pressure and temperature
in the refrigerant tank. It is used to
eliminate incondensable gases and helps
to limit the pressure in the refrigerant
tank.
Calibration Check
To check the calibration of the internal
scale. See Checking the calibration in the
Maintenance section of this manual.
Adjust Zero Offset
To reset the exhausted oil scale to zero.
Display Title Info
To activate or deactivate the station
pressure displaying.
System Information
Displays the revision level of the station
software.
Periodic Leak Test
Performs a pressure test to detect any
leakage on the station.
Service Menu
Reserved for use by Bosch service
centers.
Production Menu
Reserved for use by Bosch technicians
only.
Calibrate Air Flow
To perform the air flow calibration.
Follow the instructions on the display.
Select
to return to the Setup Menu.