INSTALLATION
Ports
VMTD001, VMTD003
VMMD001, VMMD002, VMMD003
SPECIFICATIONS
0.38
[0,97]
VMMD Models
"P" — Pressure Port
"R" — Return-to-Tank Port
"C1" — Cylinder 1 Port
"C2" — Cylinder 2 Port
CAUTION
Pressure on the return-to-tank port "R" must not exceed 250 psi [17,3 bar].
Mounting Bracket
Mount this valve directly onto a flush surface using the bracket provided. The bracket
can be repositioned on any side of the valve, or removed for panel mounting.
Use a straight fitting connector on the port where the bracket is positioned. Angle or
"Tee" style fittings may not clear the mounting bracket.
Panel Mounting
Remove the mounting bracket. The panel cutout diameter is 1.41 inches [3,58 cm] into a
maximum plate thickness of 0.25 inches [0,64 cm]. The valve can be secured into the
panel plate using the supplied locking nut.
Mount these valves onto single- or multiple-station
manifolds. The four hole mounting pattern on the
valve is offset to prevent incorrect placement on to
the manifold. See Figure 3.
Valve Type
Interface
VMMD001
D03
VMMD002
CETOP 03
VMMD003
DO3
1.96
[4,98]
3.13
[7,95]
®
PRODUCTION AUTOMATION
1
2
MAX. PRESS.
P
R
SN XXXXXX
5000 PSI
CYL1
Figure 1
P
1
R
VMMD Models
Mounting Screws
#10-24
M5
`
#10-24
2
ø 0.28
ø [0,71]
2.73
[6,93]
3.13
[7,95]
PRODUCTION AUTOMATION
VMTD-001
MAX. PRESS.
5000 PSI
VMTD
P
C1
P
1 2
R
2
R
VMTD
Figure 2
1.60
[4,05]
.85
[2,16]
.45
[1,14]
.88
[3,45]
.69
[1,75]
Figure 3
®
1
2
P
R
SN XXXXXX
C1
C2