MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Before
carrying
operation, disconnect the device from the
power supply.
1 Frequently check installation in order to discover any
imbalance or signs of deterioration or wear. Do not
use the device if any repair or adjustment is
necessary.
2

FAILURE DIAGNOSIS

Problem
The operator does not make any
movement when the opening or
closing transmitters are activated
By activating the opening or closing
transmitters, the operator is enabled
but the gate does not move
The gate moves in an irregular
manner
The gate cannot completely close (or
open)
3

SCRAP

The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
4

SPARE PARTS

If the operator needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
54
Installation manual
out
any
maintenance
Cause
A b s e n c e o f s y s t e m p o w e r
voltage
Defective electrical installation
Defe ctive control pane l or
control devices
Pins stuck in the bushing
De-aligned pins
T h e p h o t o c e l l d e t e c t s a n
obstacle
The resistance of the gate has
increased when closing (or
when opening)
The force of the operator during
closing (or opening) is too low
The mechanical stoppers of the
gate are maladjusted
2 Clean and lubricate the articulations and rails of the
gate, so as not to increase the effort of the operator.
3 Check that the controls and photocells, as well as
their installation, have not suffered any damage
from the weather or external agents.
Solution
Re-establish the power supply
voltage
Check that the installation does not
present any short-circuits or cut-off
points
Check these elements, seeing their
respective manuals
Unblock and adjust the gate pins
Align the pins
Eliminate the obstacle and try again
Check the moving parts of the gate
and eliminate the resistance
Using the control panel programme,
increase the closing or opening force
Adjust the stoppers
}
The operator must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not controlled, as this will cause
environmental damage.
Use only original spare parts. See the figure
"Content and spare parts" on page 43.