WARNING
Filter replacement may only be performed by trained personnel. Use a protective mask and suitable
equipment.
Release and lift off the upper part for free access to the filter. Lift the filter straight up. If appropriate, fit a plastic bag over the
cyclone to prevent the dust in the filter from spreading. Check the gasket when replacing the filter. A worn gasket can allow
hazardous dust to escape. Never use old gaskets or non-OEM parts. Place used filters in a plastic bag and seal the bag. See
instructions below.
1
Turbo pump
The turbo pump has a very long service life without any special maintenance. After approx. 10,000 operating hours, the radial
seal between the motor and the turbo pump must be lubricated with grease. Bearings and seals, in both the motor and pump,
must be checked and lubricated. Worn parts must be replaced.

Regular checks

Regularly check the power cord for damage.
The machine must be tested and inspected at least once a year due to its use with hazardous materials. Worn parts must be
replaced. Never risk functionality and service life. Only use genuine parts.

Warranty

The warranty period is two years and covers manufacturing defects. The warranty is valid on condition that the machine is used in
the normal way and receives the required service. Normal wear and tear is not covered. Repairs must be carried out by
Dustcontrol or personnnel authorized by Dustcontrol. Otherwise, the warranty is void.

Troubleshooting

Problem
Cause
Motor not running.
Power supply not connected.
Motor protection tripped.
Motor stops
Incorrect fuse.
immediately after
Motor protection tripped.
starting.
2
3
DC 5800, Art.nr. 94269-B
4
Action
Connect power supply.
Investigate why the motor has overloaded and rectify. Note that
if the machine has been operating with too much throttle, the
motor protection has tripped to protect against overheating.
Wait for 5 minutes. Reset by first turning to 0 position and then
to start position. See picture below the table.*)
Replace with correct fuse.
Investigate why the motor has overloaded and rectify. Note that
if the machine has been operating with too much throttle, the
motor protection has tripped to protect against overheating.
Wait for 5 minutes. Reset by first turning to 0 position and then
to start position. See picture below the table.*)