Maintenance intervals
Tilt the machine in the maintenance
position
The escalator cleaner must be accessible
from the bottom side to perform any testing
or maintenance jobs on the machine.
Take the help of another person to tilt
the machine forward until it stands on
the front casing.
Daily before use
Check spray pattern of the nozzles.
Check if suction nozzles are dirty.
Check emergency stop function of the
foot pedal.
Press the foot pedal, set the appliance
switch to 'dry vacuum cleaning', the ap-
pliance must run. Release the foot ped-
al; the appliance must stop.
Get the machine repaired only by au-
thorised customer service agents.
Check the locking of the rear wheels.
Get the machine repaired only by au-
thorised customer service agents.
Check for wear and tear:
Roller brushes, intake brushes, combs,
guide rails, hoses, stopper and front
wheels. Replace stopper and front
wheels, if required, only through author-
ised customer service agents.
Check mains cable and plug for dam-
age or breakage. Get them replaced
only through customer service agent or
an electrician.
After 100 operating hours
Check if all fasteners are fastened tight-
ly.
Check the drive belt for tension and
wear (Customer Service).
Maintenance Works
Clean the fluff filter
Unscrew the tin cover plate using a torx
spanner.
Note:
A hexalobular key (Torx) can be found in
the waste water drain hose support.
Clean the fluff filter.
Replace the tin plate.
EN
– 8
1
2
23