Herunterladen Inhalt Inhalt Diese Seite drucken

Emptying The Plant - Sime Logo OF TS serie Anweisungen Für Den Installateur

Vorschau ausblenden Andere Handbücher für Logo OF TS serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

tee. a. supply. of. gas. sufficient. to. cover.
the.maximum.demand,.limiting.pressure.
loss. between. the. gas. meter. and. any.
apparatus. being. used. to. not. greater.
than:
–. 1.0. mbar. for. family. II. gases. (natural.
gas);
–. 2.0.mbar.for.family.III.gases.(butane.or.
propane).
A. sticker. inside. the. module. includes.
identification. and. gas. type. data. specific.
to.the.module.
2.2.1 D.H.W. tank unit "BT130 -
BT150"
The."22 OF TS - 32 OF TS".versions.can.
be.matched.to.the.separate.D.H.W..tank.
units."BT130-BT150"..
The. D.H.W.. tank. . units. can. be. installed.
underneath. the. boiler. ("BT150"). or. on.
the. side. ("BT130").. The. D.H.W.. sensor. .
(SB).is.supplied.with.the.tank..
The. SB. must. be. connected. to. the. elec-
tronic. control. panel. of. the. boiler. as.
shown. in. fig.. 6.. To. aid. installation. an.
optional.hydraulic.connection.kit.is.avai-
lable,. code. 8076104. ("BT130"). and. code.
8076105.("BT150")..
Detailed. instructions. on. assembling. the.
kit.are.given.in.the.packaging.
2.2.2
Filter on the gas pipe
The. gas. valve. is. supplied. ex. factory. with.
an.inlet.filter,.which,.however,.is.not.ade-
quate. to. entrap. all. the. impurities. in. the.
gas.or.in.gas.main.pipes..
To.prevent.malfunctioning.of.the.valve,.or.
in.certain.cases.even.to.cut.out.the.safety.
device. with. which. the. valve. is. equipped,.
install.an.adequate.filter.on.the.gas.pipe.
2.4
SYSTEM FILLING (fig..4)
The.filling.is.carried.out.at.a.boiler.tem-
perature. no. less. than. 40°C.. It. is. done.
slowly.in.order.to.allow.the.air.bubbles.to.
be. released. through. . appropriate. vents..
In.order.to.facilitate.this.operation.posi-
tion.the.set.screw.slot.of.the.non.return.
valves. horizontally.. Once. the. filling. is.
completed. put. the. screws. back. in. the.
starting.position..The.loading.pressure.of.
the.un-started.plant.should.be.1.bar..
Once the filling has been completed,
close the filling tap.
2.4.1 Emptying the plant
To. carry. out. this. operation. act. on. the.
discharge.tap.(4.fig..3.-.8.fig..3/a.-.10.fig..
3/b).. Before. carrying. out. this. operation.
check.that.the.filling.tap.is.closed.
10
OPEN
APRE
KEY
1.Filling.cock
2.Non.return.valve
2.5
FLUE
The.flue.for.the.atmospherical.expulsion.
of.the.combustion.products.from.natural.
draught. appliances. must. meet. the. fol-
lowing.requirements:
–. Be. gas-tight. to. the. combustion. pro-
ducts,.waterproof.and.thermally.insu-
lated.
–. Be.built.of.materials.suitable.for.keep.
resisting.to.normal.mechanical.stres-
ses,.heat,.and.the.action.of.combustion.
products.and.their.possible.condensa-
tes.
–. Follow. a. vertical. path. and. not. pre-
sent. any. throttling. throughout. its.
entire.length.
–. Be. adequately. insulated. to. prevent.
phenomena. of. condensation. or. smo-
kes. cooling,. in. particular. if. located.
outside. the. building. or. in. unheated.
ambiences.
–. Be. set. at. an. adequate. distance. from.
combustible. or. easily. inflammable.
material. by. means. of. an. air. gap. or.
suitable.insulating.material.
–. Have. beneath. the. mouth. of. the. first.
smoke. duct. a. chamber. for. collecting.
2
solid.material.and.any.condensate;.the.
height.of.the.chamber.must.be.at.least.
500.mm..
. Access. to. the. chamber. must. be. gua-
ranteed.by.means.of.an.opening.provi-
ded.with.an.air-tight.metal.door.
–. Have. a. circular,. square,. or. rectan-
gular. internal. cross. section;. in. the.
1
case. of. square. or. rectangular. sec-
tions,. the. corners. must. be. rounded.
off. with. a. radius. of. not. less. than. 20.
mm.. However,. hydraulically. equiva-
lent.cross.sections.are.allowed.
–. Be. equipped. with. a. chimney-pot. at.
the.top,.which.must.be.outside.the.so-
called.back-flow.zone,.so.as.to.prevent.
the.formation.of.back-flow,.which.pre-
vents.free.discharge.of.the.products.of.
combustion.into.the.atmosphere.
Fig..4
–. Be. devoid. of. mechanical. means. of.
suction.located.at.the.top.of.the.pipe.
–. No.overpressure.should.be.present.in.
a.chimney.that.passes.within.or.close.
up.to.inhabited.rooms.
2.5.1
Connecting up flue
Fig..5.refers.to.the.connection.of.the.boi-
lers.to.the.flue.or.chimney.through.smoke.
ducts.for.apparatus.of.nominal.heat.input.
not.greater.than.35.kW..
When. making. the. connection,. in. addi-
tion. to. respecting. the. dimensions. given,.
you. are. recommended. to. use. gas-tight.
materials. capable. of. resisting. over. time.
mechanical. stresses. and. the. smokes.
heat..
At. any. point. along. the. smoke. duct,. the.
temperature. of. the. combustion. products.
must.be.higher.than.the.dew.point..
More. than. a. total. of. three. changes. of.
direction. must. not. be. made,. including.
the. inlet. connection. to. the. chimney/flue..
For. any. changes. of. direction. use. only.
curved. pipe. lengths.In. case. of. having. to.
go. through. combustible. walls,. insulation.
Fig..5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Logo 22 of tsLogo 32 of ts