Herunterladen Inhalt Inhalt Diese Seite drucken

On-Wall Mounting - Grasslin thermio essential smart Bedienungsanleitung

Raumthermostat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Closing the housing
8.
Place the housing cover on the housing base and tighten the screw on the device housing with the
Phillips screwdriver.

On-wall mounting

Personal:
Qualified electrician
Removing the housing cover
1.
Undo the screw on the device housing with the Phillips screwdriver and remove the housing cover.
2.
Mark the hole pattern from the housing base onto the wall and drill holes at the points you marked
(5 mm diameter and at least 25 mm deep).
3.
Insert the wall-plugs provided into the holes.
Connecting
4.
Strip the connection wires to a length of 8 mm (cross-section between 1 mm² and 2.5 mm²).
5.
Thread the connection wires into the device through the cable feed-through (Fig. 1/7).
50

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis