7
Manufacturer's information
7.1
Transport
Only transport the valve by suitable
G
means. Do not drop. Handle carefully.
Dispose of packing material according
G
to relevant local or national disposal
regulations / environmental protection
laws.
7.2
Delivery and performance
The valve is supplied fully assembled.
The operator instructions are included
separately. The scope of delivery is apparent
from the dispatch documents and the design
from the order number. The performance of
the valve was checked at the factory.
The valve's delivery condition:
Control function:
0 Manually operated
1 Normally closed (NC)
2 Normally open (NO)
3 Double acting (DA)
Check that all parts are present and
G
check for any damage immediately upon
receipt.
7.3
Storage
Store the valve free from dust and
G
moisture in its original packaging.
Store the manual valve in the "open"
G
position.
Avoid UV rays and direct sunlight.
G
Maximum storage temperature: 40 °C.
G
Solvents, chemicals, acids, fuels or
G
similar fl uids must not be stored in the
same room as valves and their spare
parts.
7.4
Tools required
The tools required for installation and
G
assembly are not included in the scope
of delivery.
Use appropriate, functional and safe
G
tools.
567
8
The GEMÜ 567 BioStar control 2/2-way
control valve is designed for use in sterile
applications. Flow rates ranging from 80 l/h
to 12,500 l/h are possible depending on the
version. The sealing concept of the valve is
based on the GEMÜ PD design. All metallic
operator components are made of stainless
steel. The valve is CIP/SIP capable.
The valve is available with a manual or
pneumatic operator. The pneumatic type is
available with Normally closed, Normally
open and Double acting control functions.
Diverse accessories are available, such as
proximity switches and locking device.
8.1
11
10
Condition:
9
8
Open
7
6
Closed
5
Open
4
3
undefined
2
1
48 / 68
Functional description
Temperature/pressure
diagram
-20 -10 0
20
40
60
Temperature [°C]
80
100
120
130
140
160