Power supply voltage U1 (50/60Hz)
Zmax (@PCC)
Slow blow line fuse
Communication bus
MMA maximum input power (kVA)
MMA maximum input power (kW)
TIG maximum input power (kVA)
TIG maximum input power (kW)
MIG/MAG maximum input power (kVA)
MIG/MAG maximum input power (kW)
Power factor PF
Efficiency (µ)
Cos
Max. input current I1max
Effective current I1eff
MMA duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
MMA duty factor (25°C)
(x=75%)
(x=80%)
(x=100%)
TIG duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
TIG duty factor (25°C)
(x=80%)
(x=100%)
MIG/MAG duty factor (40°C)
(x=50%)
(x=60%)
(x=100%)
MIG/MAG duty factor (25°C)
(x=80%)
(x=100%)
Adjustment range I2
Open circuit voltage Uo
IP Protection rating
Insulation class
Dimensions (lxdxh)
Weight
Manufacturing Standards
Power supply cable
Length of power supply cable
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment complies with EN/IEC 61000-3-12 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
38
URANOS 5000 PME
3x400Vac ±15%
49mΩ *
30A
DIGITAL
23.6 kVA
22.5 kW
18.2 kVA
17.4 kW
22.9 kVA
21.9 kW
0.95
88%
0.99
33A
23.9A
500A
470A
420A
-
500A
470A
500A
470A
420A
500A
470A
500A
470A
420A
500A
470A
3-500A
73Vdc
IP23S
H
690x290x510 mm
37 kg.
EN 60974-1
EN 60974-10
4x4 mm2
5 m