4.5
Re-establishing factory settings
!
Then check the cut-out points and correct if neces-
sary.
i
Only perform this function if operating mode "0" can
no longer be activated.
1. VLE 2130 / 2130 FSwitch off the .
2. Fit the factory settings jumper (refer to Fig. 4,
Item 2).
3. VLE 2130 / 2130 FSwitch on the .
LED1 and LED2 flash (green/orange).
4. Wait three seconds.
5. Switch off the VLE 2130 / 2130 F.
6. Remove the factory settings jumper (refer to Fig. 4)
(jumper not fitted).
7. Switch on the VLE 2130 / 2130 F.
8. Set the encoding switch to "0".
9. Confirm with <ENTER>.
LED 1 and LED 2 light (green).
This selects operating mode.
10. Press and hold the button o (raise).
The main column and secondary column support
arms move upwards.
11. Move the support arms to a height of approx. 50 cm.
12. Set the encoding switch to "8".
13. Confirm with <ENTER>.
This selects Activation/diagnosis function mode.
LED1 and LED2 flash (red/green).
Acoustic signal sounds intermittently.
14. Press and hold the button o (raise).
LED1 lights (red), LED2 off.
LED1 off, LED2 lights (red).
LED1 and LED2 light (red).
The main column and secondary column sup-
port arms move upwards.
The main column and secondary column sup-
port arms stop.
15. Release the button o (raise).
LED1 and LED2 flash (orange/green).
|
1 689 978 550
2017-07-14
16. Press and hold the button u (lowering).
LED1 lights (orange), LED2 off.
LED1 off, LED2 lights (orange).
LED1 and LED2 light (orange).
The main column and secondary column sup-
port arms move downwards.
The main column and secondary column sup-
port arms stop.
17. Release the button u (lowering).
LED1 and LED2 flash (green).
18. Set the encoding switch to "0".
19. Confirm with <ENTER>.
LED1 and LED2 flash (green).
Buzzer stops sounding.
"
Activation successfully implemented.
!
If a fault occurs during the test, the platform can-
not be operated in "0" setting. The test can only be
repeated after interrupting the power supply.If the
jumper is then not removed, the factory settings will
be loaded again the next time the platform is swit-
ched off and on.