Installation
Flash through the supply pipes.
Install box depending on the building application.
Watch the depth of installation (see sticker on the
installation box).
Large differences in pressure between the hot and cold
water supply should be balanced.
The hot water connection must always be LHS and the
cold water connection RHS. The mixed water outlets in
the top and bottom of the housing can be used singly
or jointly as required. For single connection the outlet
not in use must be properly sealed with the screw plug.
Stop valve(s) must be provided to control
the flow of mixed water from the outlet(s).
After completion the whole installation must be flashed.
For this action the cold water and mixed water pipes are
connected in the flushing unit. The hot water supply
pipe is lfushed on the flushing unit, the cold water and
mixed water supply pipes on the outlets. Afterwards
check the pipes and connections for leakage.
Important!
In the event of frost hazard and draining the pipes, the
flushing unit must be removed and the thermostatic
mixer body drained.

Final installation

Finish sets ½" and ¾"
Mondaro
Starck
Arco
Allegroh
Steel
Azzur
Terrano
Carlton
Uno
Mondial / Metropol /
Metris / Talis Elegance /
Talis Sportive
18375XXX
10375XXX
11375XXX
36375XXX
35375800
34375XXX
37370XXX/37375XXX
17375XXX/17377XXX
13375XXX
15375XXX
English

Technical data

Minimum flow pressure with
downstream resistance
Max. operating pressure
Recommended operating pressure
Test pressure
Max. hot water temperature
Temperature scale adjustible
Safety check
Hot water connection
Cold water connection
Nominal capacity for ½" and
¾" by 3 bar
Minimum flow rate
The water temperature at the hot water inlet should be
at least 2° C higher then the desired hot water
temperature.
The Hansgrohe ½" thermostatic mixer (code number
15373180) and ¾" (code number 15374180), can
be used in conjunction with hydraulic or thermostatically
controlled combination boilers providing there is a
minimum of 1,5 bar pressure and the combinaton boiler
prepare enough water for the downstream consumption.
0,5 bar
10,0 bar
1,0 - 5,0 bar
16,0 bar
80° C
20° - 80° C
38° C
LH
RH
50 l/min
5 l/min