Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch WBE 4140 Instandsetzungsanleitung Seite 34

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. Move the slides with distance A and width B to
standby position and press <OK>.
3. Move the reading cursor of distance 0 mm. Set the
value read and press <OK>.
4. Move the cursor of distance A against the interior of
the flange. Measure and set the value read and press
<OK>.
5. Keeping the distance A cursor in standby, move the
cursor of width B width against the external part of
the flange and press <OK>.
6. Assemble the width calibration pin on the external
part of the flange. Move the width cursor against the
end of the pin and press <OK>.
Robert Bosch GmbH
Standard calibration | WBE 4140 | ��
7. Remove the pin and assemble a 14'' or 15'' steel
sample wheel using the relevant hold-down nut.
8. Set the wheel measurements and, with the distance
reading cursor resting on the wheel itself, press
<OK>.
 Procedure completed.
!
Valid procedure with updated SW 6.16 version,
otherwise proceed with the software upgrade.
en
|
1 695 655 779
2010-11-9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis