detected further movements and has restarted the switching
duration several times.
1 Setting the switching duration (Figure _):
– Left stop: switching duration approx. 1 s
– Right stop: switching duration approx. 8 min
How to mask individual areas
When there are sources of interference such as trees, bushes or lights in
the area of detection of the ARGUS, and these trigger the load
accidentally, you can mask them using the segments supplied
(Figure •):
1 Place the inserts exactly on those areas of the sensor head (A)
which should be masked from detection, and press them onto the
sensor head (B).
Note:The light-sensitive sensor C at the front must not be covered
|
by segments, since this reduces the light sensitivity.
Technical data
½
Caution! Operation only possible with sinusoidal mains voltages.
Phase control dimmers or inverters with square wave or trapezoidal
voltage curves will damage the device.
Mains voltage:
AC 230 V ±10%, 50 Hz.
Fuse the ARGUS using a 16 A automatic
circuit-breaker.
16 A, AC 230 V, cos ϕ = 1
Max. switching current:
Nominal capacity:
Incandescent lamps AC
max. 2000 W
230 V:
Halogen lamps AC 230V: max. 2000 W
Fluorescent lamps AC
230 V:
max. 1200 W, uncompensated
How to mask individual areas
19
Technical data
max. 35 µF
Capacitive load:
Transformer load:
max. 600 VA
Power consumption:
< 1 W
Connecting terminals:
for 2 x 1.5 mm
conductor, stripped to 14 mm
External diameter of a
cable:
max. 14.5 mm
Interface:
for expansion with a radio module (565495)
for wireless connection of several devices
Area of detection:
220°
Range:
max. 16 m
Number of levels:
7
Number of zones:
112 with 448 switching segments
Minimum mounting
1.7 m
height:
Recommended mounting
2.5 m
height:
Sensitivity:
infinitely adjustable
Light sensor:
infinitely adjustable externally
approx. 3–1000 lux
Switching duration:
can be set externally at 6 levels
approx. 1 s – approx. 8 min
Possible settings for
sensor head
Wall mounting:
9° up, 24° down, 12° left/right, ± 12° axial
Ceiling mounting:
4° up, 29° down, 25° left/right, ± 8.5° axial
Type of protection:
IP 55 at an angle of inclination from 15° to
90°
EC guidelines:
Low-voltage guideline 73/23/EEC and EMC
guideline 89/336/EEC
20
2
2
or 2 x 2.5 mm
rigid