Remedy of faults
Malfunction
Lamp does not light up
Luminosity decreases
Water inside the spotlight housing
S
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
· Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
10
Cause
Power supply interrupted
Bulb defective
Lamp glass soiled
The brightness of the bulb reduces as the oper-
ating time increases
Seal defective
www.oase-livingwater.com/spareparts
Remedy
Check power supply
Replace bulb
Clean
Replace bulb
Check sealing rings and replace, if necessary