Herunterladen Inhalt Inhalt Diese Seite drucken

General Safety Instructions ����������������������������������� 50 18.1 Estimated Current Intensity; Safety �������������������������������������������������������� 50 Specification; Instructions, Standards And Regulations; Appliance Description - STIEBEL ELTRON WPE-I 33 H 400 Premium Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für WPE-I 33 H 400 Premium:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION
Safety
INSTALLATION
7.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
The tested appliance conforms to IEC 61000-3-12.
8.

Appliance description

The heat exchanger on the heat source side (evaporator) extracts
natural heat from the heat source. This extracted energy and the
energy drawn by the compressor drive is transferred to the heating
water by a heat exchanger on the heating water side (condenser).
Subject to the heat load, the heating water is heated up to +65 °C.
If the heat demand of the heating system exceeds the heating
output of the heat pump, the booster heater covers the residual
heat demand.
If the hot gas function is used, the heat pump can be used to
achieve DHW temperatures over 60 °C when heating without a
booster heater. The compressed refrigerant transfers the energy
absorbed by the compressor to the DHW in a hot gas heat ex-
changer. The refrigerant then flows into a second heat exchanger
in which the energy is transferred to the heating water.
Outside the heating season, DHW heating can be supported by a
booster heater.
The heat pump is not suitable for dry heating the screed.
8.1

Standard delivery

The following are delivered with the appliance:
- Outside sensor
- Immersion / contact sensor
- Split ferrite
50
| WPE-I H 400 Premium
8.2

Accessories

- Extension module EM WPE-I 33-87
- Hot gas set HG set WPE-I 33-87
- Remote control FE WPE-I 33-87
- Instantaneous water cylinder SBS 601-1501 W (SOL)
- Electric threaded immersion heater BGC 2/60
- Buffer cylinder (for cooling)
WPE-I 33 H 400 Premium  | WPE-I 44 H 400 Premium
- Pressure hose SD 32-0.6 G
- Pressure hose SDB 40-0.8 G
WPE-I 59 H 400 Premium  | WPE-I 87 H 400 Premium
- Pressure hose SD 40-0.8 G
- Pressure hose SDB 50-0.8 G
9.

Preparation

Note
The appliance is designed for indoor installation, except
in damp areas.
9.1

Sound emissions

Note
For details regarding the sound power level, see the
chapter "Specification / Data table".
- Never site the appliance on joist floors.
f Ensure that the entire appliance frame is in full contact with
f
the substrate. Uneven substrates can increase sound emis-
sions.
f Never install the appliance directly below or next to a living
f
room or bedroom.
f Avoid installation on large, echoing floor areas, e.g. tiled
f
floors.
f Avoid installation between reflective building walls. Reflect-
f
ing building walls can increase the noise level.
f Never install the appliance in the corner of the installation
f
room.
f Implement pipe outlets through walls and ceilings with an-
f
ti-vibration insulation.
f Use flexible supply lines.
f
f Secure the supply lines with structure-borne noise attenua-
f
tion on noise-sensitive walls.
f Ensure that the appliance feet are aligned.
f
www.stiebel-eltron.com

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wpe-i 87 h 400 premiumWpe-i 59 h 400 premium

Inhaltsverzeichnis