Pointek CLS500
Note: Pointek CLS500 is to be used only in the manner outlined in this manual, otherwise
protection provided by the equipment may be impaired.
This product is intended for use in industrial areas. Operation of this equipment in a
residential area may cause interference to several frequency based communications.
Pointek CLS500 is a 2-wire capacitance point level switch for detecting interfaces, solids, liquids,
slurries and viscous materials in critical conditions of extreme temperature and extreme pressure.
Approvals (verify against device nameplate)
• CE, C-TICK
• CSA, FM, ATEX
• Bureau Veritas, Lloyd's Register of Shipping, categories ENV1, ENV2, ENV3, and ENV5
Note: The use of approved watertight conduit hubs/glands is required for Type 4X /
NEMA 4X, Type 6 / NEMA 6, IP65, IP68 (outdoor applications).
Process connections
• Threaded
• Flat-faced flange
Ambient conditions
• general applications
Process conditions
Please see full Operating Instructions for Process Pressure/Temperature De-
Note:
rating Curves.
• relative dielectric constant (ε
Temperature rating
• Standard (PFA)
• High temperature stainless steel version with enamel insulation and thermal insulator
• High temperature stainless steel version with thermal isolator
Pressure rating
• Standard (PFA)
• High temperature version (enamel)
• High temperature version (stainless steel)
Page EN-2
NPT [(Taper), ANSI/ASME B1.20.1], R[(BSPT), EN 10226/PT (JIS-T),
JIS B 0203], G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
ASME, EN 1092-1
-40 to +85 °C (-40 to +185 °F)
)1.5 minimum
r
-50 to +200 °C (-58 to +392 °F)
-60 to +400 °C (-76 to +752 °F)
-60 to +400 °C (-76 to +752 °F)
-1 to +150 bar g (-14.6 to +2175 psi g)
-1 to +345 bar g (-14.6 to +5004 psi g)
-1 to +35 bar g (-14.6 to 507.6 psi g)
Pointek CLS500 – QUICK START MANUAL
7ML19985XS81