Warning: If, after first installation, after a long period of inactivity or after a period of heavy use, your ppm level is
low (<0.5ppm), you can adjust the production to 100% or use the boost feature (see BOOST).
2 –Winter production temperature
Water temperature adjustment for winter shutdown. Adjustable range: from 5°C to 20°C. Factory value: 15°C.
Once the setpoint temperature has been reached, chlorine production is automatically regulated to ensure the
minimum disinfection and optimise the electrodes' life span. The message iWINTERi appears on the main screen to
indicate that it is in winter mode.
The purpose of this feature is to allow users to run the device throughout the entire year, in order to avoid the
inconveniences of restoring the water to proper conditions after winter, thereby optimising maintenance
expenses.
3 –Winter production temperature
Water temperature adjustment for winter shutdown. Adjustable range: from 5°C to 20°C. Factory value: 5°C.
Once the setpoint temperature has been reached, chlorine production is stopped to prevent irreversible damage to
the electrodes. In this case, you are advised to remove the cell from the vessel and to put the electrode into winter
mode (see maintenance handbook). This parameter is treated as if it were an alarm. The message iWINTERi is
displayed on the main screen and the LED light
2 – pH Menu
1 – Deactivate pH
2 – Setting pH
3-Sensor calibration
4-Return to menu
minutes, the value becomes stable.
Warning: Upon starting up the device, check to make sure the pH in the water is between 6 and 8.
Note : At the time of the first installation or when changing the pH- correcting agent tank, it may be necessary to
start up the pump in such a way that the neoprene tube is filled with correcting agent. To do this, place your cursor
on 1-Activate auto-test in the menu Auto-test. Press the knob for 5 seconds. The pump is activated for 2 minutes.
Repeat this process if necessary.
1 – Deactivate pH
This option is only available in the models with pH regulation or dynamic models.
Models with pH regulation: this feature is activated by default (value shown on the main screen). It may be
deactivated for all handling of the sensor or for operation without pH regulation.
Dynamic models (EVO) without the pH option: this feature is deactivated by default (display on main screen: pH:
This feature will be activated after installation of the pH kit by the user (dynamic change to pH regulation).
2 – Setting pH
Adjustment of the pH setting (6.8~7.5). Factory setting of 7.3.
It is advised to have a pH setpoint of less than 7.3 for maximum chlorine disinfection effectiveness.
3-Sensor calibration
The sensors are calibrated upon leaving the factory. However, it is recommended to perform calibration upon
installation of the sensor.
The calibration must be verified at least once per year.
STATUS
The pH value displayed on the main screen is the level measured in your swimming
pool.
Warning: The values may vary (+/-) momentarily after handling the sensor
(calibration, maintenance, replacement, etc.) or after stopping the pump. This is
normal and does not mean the sensor has malfunctioned in any way. After a few
gets red.