CAUTION
• Exposure of unit to water or other moisture before installation could result in electric shock.
Do not store it in a wet basement or expose to rain or water.
• After unpacking the unit, examine it carefully for possible damage.
• Do not install the unit at place where leakage of À ammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause of ¿ re.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and
discharged air might disturb neighbors.
• To avoid personal injury, be careful when handling parts with sharp edges.
• Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.
• The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.
Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems
or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.
Important information regarding the refrigerant used
This product contains À uorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R32
GWP
(1)
value: 675 *
(1)
GWP = global warming potential
The refrigerant quantity is in dicated on the unit name plate.
* This value is based on F gas regulation 517/2014
No.
1
3
5
7
No.
9
* Not require to use for RAS-05, 07, 10, 13BAVG-E
Air ¿ lters
Clean every 2 weeks.
1. Open the air inlet grille.
2. Remove the air ¿ lters.
3. Vacuum or wash and then dry them.
4. Reinstall the air ¿ lters and close the air inlet grille.
01_1118350101-1 EN.indd 2
REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER

ACCESSORY PARTS

Indoor Unit
Part name
Installation Plate × 1
Battery × 2
Mounting screw × 6
Owner's Manual × 1
Outdoor Unit
Part name
Drain nipple × 1
No.
2
Wireless remote control × 1
4
Remote control holder × 1
6
Flat head wood screw × 2
8
Installation Manual × 1
No.
!
Cap water proof × 2*
2
Part name
Part name