5.3.2
Pressure ranges
WarnIng!
risk of bursting due to overpressure!
If the device bursts, there is a risk of serious injury, chemical burns,
scalding.
▶ Do not exceed the maximum pilot and medium pressure. Observe
specifications on the rating plate.
permitted pilot- and medium pressure:
control
Minimum
Maximum
function
pilot
pilot
(cf)
pressure
pressure
[bar]
[bar]
CFA
5.5
CFB
2.2
required minimum pilot pressure for control function B
depending on the medium pressure on one side:
10
8
6
4
2
0
1
2
3
4
pilot pressure [bar]
Fig. 1:
Pressure graph, elastomer and Advanced PTFE diaphragm
6
Maximum medium pressure
[bar]
elastomer
ptfe and
(including
advanced
coated)
ptfe
10
10
7
see "Fig. 1"
Elastomer
(including coated)
PTFE and
Advanced PTFE
5
6
7
english
5.3.3
Permitted media
Control medium:
Flow media:
5.4
control functions
A
A
P
A
B
P
5.5
Type label
6
Orifice (Diaphragm size)
Control function
Type
Serial number
Fig. 2:
Description of the type label
Type 2031 INOX
Technical data
neutral gases, air
neutral gases and liquids, high-purity, sterile,
aggressive and abrasive media
Closed in rest position by spring force
Open in rest position by spring force
Seal material
Body material
2031 A 8,0 EPDM VA
Connections, Max.
G1/4
Pmed 8,5 bar
medium pressure
Pilot 5,5-10 bar
Pilot pressure
S/N 1060
00445286
W36LP
Identifications number