The dryer control board is equipped with a digital output for the remote signalling alarm. This digital
output is controlled by a relays configured as normally open: when an alarm is detected, this relays
closes a circuit.
Proceed as follows to activate a remote alarm output:
1.
The User must provide a signaller in compliance with output relays electrical features
(solenoid coil, light bulb, acoustic signaller, ...).
2. Disconnect the dryer from electrical power supply, remove cover and left side panel.
3. Connect the signaller to the terminal blocks (See PIC.2).
Alarm Output relays electric features: 250VAC / 3A – AC 15 (Amp. Inductive)