Operating instructions
LCD Display counters
Type C C o o d d i i x x 130/131/132/133
The 13X display counters are battery-powered. They
are controlled by contact or voltage pulses. They may
be used in various applications, like e. g. totalising,
parts counting, position acquisition, differential coun-
ting, etc. In addition, the various models with specific
input types may be extended using control inputs to
select operatin modes and set for almost any applica-
tion thanks to adjustable operating modes.
1.1 Preface
Please read this instruction manual carefully before
installation and start-up. Please observe all
warnings and advices, both for your own
safety and for general plant safety. If the
device is not used in accordance with this
instruction manual, then the intended protection can be
impaired.
1.2 Safety Instructions and Warnings
Please use the device only if its technical
condition is perfect. It should be used only
for its intended purpose. Please bear in
mind safety aspects and potential dangers
and adhere to the operating instructions and
to this addendum at all times. The safety standards in
force for electrical installations are also to be adhered
to.
1.3 Use according to the intended purpose
The application area for this device lies in industrial
processes and controls, in the fields of manufacturing
lines for the metal, wood, plastics, paper, glass, textile
and other like industries with a degree of contamination
of 2. Over voltages at the terminals of the device must
be kept within the limits of Over voltage Category II.
The device is not suitable for use in hazardous areas
and for areas excluded from EN 61010 Part 1. The
device may only be operated indoors as a panel-
mounted device. However, in certain conditions, an out-
door operation is also allowed. It may be operated up
to an altitude of 2,000 m. Use for any purpose over and
beyond this will be deemed as not in accordance with
its intended purpose.
If the device is used to monitor machines or processes
in which, in the event of a failure of the device or an
error made by the operator, there might be the risk of
damaging the machine or causing an accident to the
operators, then it is your responsibility to take the
appropriate safety measures.
6
1.4 Mounting in a control panel
Mount the device away from heat sources
!
and avoid direct contact with corrosive liq-
uids, hot steam or similar. When mounting
the device, make sure it is sufficiently cooled.
1.5 Mounting instructions
– Remove the mounting clip from the device.
– Insert the device from the front into the panel cut-out,
ensuring the front-panel gasket is correctly seated.
– Slide the fixing clip from the rear onto the housing,
until the spring clamps are under tension and the
upper and lower latching lugs have snapped into
place.
1.6 Elektrische Installation
This device is powered
!
by an internal battery
– In order to respect the fire protection regulations,
8 A/150 VA shall not be exceeded on the counter in
case of a defect!
– Do not wire the terminals of the device that are not
used.
– The pin assignment of the connectors, as well as the
maximum admissible values, must obligatorily be
observed.
– An EMC-compliant installation is a prerequisite to
reach EC conformity.
1.7 Advice on noise immunity
All connections are protected against external sources
of interference. The installation location should be cho-
sen so that inductive or capacitive interference does
not affect the device or its connecting lines!
Interference (e.g. from switch-mode power supplies,
motors, clocked controllers or contactors) can be
reduced by means of appropriate cable routing and
wiring.
1.8 Measures to be taken:
– Use only shielded cable for signal and control lines.
– Connect cable shield at both ends.
– The conductor cross-section of the cables should be
a minimum of 0.14 mm².
– The shield connection to the equipotential bonding
should be as short as possible and with a contact
area as large as possible (low-impedance).
– Only connect the shields to the control panel, if the
latter is also earthed.
– In case of problems due to ground loops, the shield is
to be connected to the reference ground, on the
reception side, with low impedance and, on the emis-
sion side, via a capacitor of approximately 100nF.
– Install the device as far away as possible from noise-
containing cables.