Herunterladen Inhalt Inhalt Diese Seite drucken

Before Starting - JAVAC CC-31 Sicherheitsanweisungen Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

EN

3.0 BEFORE STARTING

Add vacuum pump oil and always check the oil level before use. Low oil level or poor quality oil will
result in premature wear and poor performance.
Install on a flat surface with adequate ventilation; allow 5cm on all sides of the pump.
Remove the intake and exhaust fitting cap and connect via a suitable hose to a manifold or suitable
circuit.
Connect to a suitable safe power source using earth leakage devices when using extension cords.
CAUTION:
• Do not use with combustible, explosive, poisonous or reactive/corrosive gases.
• Do not allow dust particles to enter the pump.
• Do not allow the pump to run to open air / atmosphere for more than 3 minutes.
• Do allow the inlet temperature of gases to exceed 80'C. Do not use in environments over 50°C.
• Not suitable for use as a compressor, transfer pump or recovery pump.
• Do not operate without oil.
• Pump surface may be hot.
• Do not block air outlet when pump is in use.
• Suitable for indoors use only.
4
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis