Herunterladen Inhalt Inhalt Diese Seite drucken

Operation - HANSGROHE Metropol S 14461 Serie Montageanleitung

Vorschau ausblenden Andere Handbücher für Metropol S 14461 Serie:
Inhaltsverzeichnis

Werbung

Important! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1.
Flush through the supply pipes.
2.
Mount the S - unions and align them.
3.
Fasten the mixer with the washers.
The hot and cold supplies must be of equal pressures.

Operation

The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
14461XXX/14464XXX: The flow is changed from bath to
shower function by pulling the knob at the upper side of
the spout. After shutting off the water flow, the mixer returns
automatically to the bath function.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections:
Rate of flow by 0,3 MPa:
anti-pollution function
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
Instantaneous heater didn't work
English
To adjust the hot water limiter on single lever mixers, please
see page 41.
No adjustment is necessary when using a continuous flow
water heater.
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
Important!
The non return valves must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).
Spare parts (see page 4)
1
2
3
4
5
6
7
max. 1 MPa
8
0,1 - 0,5 MPa
9
1,6 MPa
10
11
max. 80° C
12
65° C
13
150 ± 16 mm
14
cold right -
hot left
XXX = Colors
ca. 20 l/min
000 = chrome plated
880 = satin chrome
Cause
- Shower filter seal dirty
- Non return valve hasn't moved back
- Aerator calcified, dirty
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
- Flow limiter in handshower isn't
removed
- Filters are dirty
- Non return valve hasn't moved back
handle
flange
nut
cartridge cpl.
flange 14461XXX/14661XXX
S-union 14461XXX/14661XXX
aerator cpl.
selector assy
diverter knob
non return valve
locking screw for handle
nut
sleeve
screw cover
Remedy
- Clean filter seal between shower
and hose
- Exchange non return valves
- Clean aerator, replace as necessary
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange non return valves
14895XXX
97406XXX
97209000
92730000
96467XXX
94140000
13914XXX
94077000
96466XXX
94074000
96059000
97927000
97738000
96338000


Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis