Device Information; Operating Limits - Dimplex LA 9TU Montage- Und Gebrauchsanweisung

Luft/wasserwärmepumpe für außenaufstellung
Vorschau ausblenden Andere Handbücher für LA 9TU:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

11

11 Device information

1
Type and order code
2
Design
2.1
Model / controller
2.2
Thermal energy metering
2.3
Installation location / degree of protection according to EN 60529
2.4
Antifreeze condensate tray / heating water
2.5
Performance levels
3

Operating limits

3.1
Heating water flow / return
Air (heat source)
4
Performance data / flow rate
4.1
Heating water flow rate /
internal pressure differential
Minimum heating water flow
2
4.2
Heat output / COP
4.3
Sound power level
4.4
Sound pressure level at a distance of 10 m (air outlet side)
4.5
Air flow
5
Dimensions, connections and weight
5.1
Device dimensions without connections
5.2
Device connections for heating system
5.3
Weight of the transportable unit(s) incl. packaging
5.4
Refrigerant; total filling weight
5.5
Lubricant; total filling quantity
6
Electrical connection
6.1
Nominal voltage; fuse protection
6.2
Starting current with soft starter
6.3
Nominal power consumption A2 W35/ max. consumption
6.4
Nominal current A2 W35 / cosϕ
6.5
Max. power consumption of compressor protection
(per compressor)
7
Complies with the European safety regulations
8
Additional model features
Type of defrosting (according to need)
1. The heat circulating pump and the heat pump controller must always be ready for operation.
2. This data indicates the size and capacity of the system according to EN 255 (10K at A2) and EN 14511 (5K at A7) without a weather-proof protective cover. For an analysis of the
economic and energy efficiency of the system, other parameters, in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consideration.
The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
3. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35°C.
4. See CE declaration of conformity
EN-8
°C
°C
A7/W35/30
m³/h / Pa
A7/W45/38
m³/h / Pa
A7/W55/45
m³/h / Pa
at A-7 / W35
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W55
kW / ---
at A10 / W35
kW / ---
dB(A)
3
dB(A)
m³/h
H x W x L mm
Inches
kg
type / kg
type / litres
V / A
A
2
kW
A / ---
W
LA 9TU
Universal / external
Integrated
Outdoor / IP24
1
Heated / yes
1
up to 58 ± 2 / from 18
-25 to +35
1.6 / 7300
1.0 / 3000
0.6 / 1100
EN 255
EN 14511
5.4 / 2.9
5.2 / 2.8
7.6 / 3.8
7.5 / 3.7
9.2 / 4.2
7.1 / 2.7
10.5 / 4.7
10.2 / 4.5
60
30
2500
1460 x 910 x 750
Thread 1 1/4" flat sealing
208
R404A / 3.4
Polyolester (POE) / 1.3
400 / 16
17
2.0 / 3.5
4.9 / 0.8
---
70; thermostatically controlled
4
Reverse circulation
LA 12TU
Universal / external
Integrated
Outdoor / IP24
1
Heated / yes
1
up to 58 ± 2 / from 18
-25 to +35
2.0 / 2900
1.3 / 1300
0.9 / 600
EN 255
EN 14511
7.8 / 3.0
7.6 / 2.9
9.5 / 3.8
9.4 / 3.7
11.6 / 4.3
10.0 / 2.7
11.9 / 4.7
11.7 / 4.6
61
32
4100
1810 x 1250 x 750
Thread 1 1/4" flat sealing
280
R404A / 4.2
Polyolester (POE) / 1.45
400 / 16
18
2.6 / 3.8
5.5 / 0.8
4
Reverse circulation