0.6 - WarNiNgs for r290 rEfrigEraNt gas
1. thE appliaNcE coNtaiNs r290 gas (flammability classifica-
tioN a3).
2. thE appliaNcE shall bE storEd iN a WEll-vENtilatEd arEa
WhErE thE room sizE corrEspoNds to thE room arEa as
spEcifiEd for opEratioN.
3. thE appliaNcE must bE iNstallEd, usEd aNd storEd iN a room With
a floor surfacE highEr thaN thE oNE iNdicatEd iN thE chart.
Quantity of r290 gas in Kg
(see data label on the
4. this appliaNcE coNtaiNs a QuaNtity of rEfrigEraNt gas
r290 EQual to thE oNE iNdicatEd iN thE data labEl locatEd
oN thE appliaNcE.
5. thE appliaNcE shall bE storEd iN a room Without
coNtiNuously opEratiNg igNitioN sourcEs (for ExamplE:
opEN flamEs, aN opEratiNg gas appliaNcE or aN opEratiNg
ElEctric hEatEr).
6. do not pierce or burn.
7. be aware that the refrigerants may not contain an odour.
8. r290 is a refrigerant gas in compliance with the European directives on
environment. do not pierce any part of the refrigerant circuit.
9. do not use means to accelerate the defrosting process or to clean, other
than those recommended by the manufacturer.
10. Do not use tools different from those recommended by the manufacturer
when defrosting and cleaning the appliance.
11. if the appliance is installed, used or stored in a non-ventilated area, the room
must be designed to prevent the accumulation of refrigerant leaks with
the consequent fire or explosion hazard due to the refrigerant combustion
caused by electrical heaters, stoves or others sources of ignition.
EN - 10
appliance)
0,120
0,130
0,140
0,150
0,160
0,170
0,180
0,190
0,200
0,210
0,220
minimum size of the site
for use and storage
m
2
6
7
7
8
8
9
9
10
10
11
11