AHWT60
AHWT35-50
ACC060TP
ACC050TP
ACC045TP
13500
12000
12000
46100
40980
40980
1.11
0.99
0.99
4.89
4.36
4.36
26
31
31
17
11
11
15
14
14
33
31
31
2
2
2
(
ﻣﻠﻢ ﻣﺮﺑﻊ
)
ﺳﻄﺢ اﻟﺘﻘﺎﻃﻊ
(
أﻣﺒﯿﺮ
)
1.5
5.5
2.5
11
2.5
11
4
16.5
2.5
11
4
16.5
2.5
10.5
4
16
4
12
4
16
4
23.5
ﻣﺴﺘﻮى اﻟﻤﯿﺎه
(
(
ﻣﻠﻢ
) (
ﺗﻨﺒﯿﮫ
/
إﯾﻘﺎف
/
ﺑﺪء
)
18/12/21
77×66×44
18/12/21
77×66×44
18/12/21
77×66×44
AMDS-CP20
م
30
م
20
م
10
13.5
15.5
17.5
12.0
14.0
16.0
10.0
12.0
14.0
8.5
10.0
12.0
7.0
8.5
10.0
6.0
7.0
8.0
ACC035TP
ACC032TP
8000
9000
27320
30736
0.67
0.99
2.95
4.36
31
23
11
9
11
14
31
24
2
2
ﻗﻮة اﻟﺘﯿﺎر
اﻟﻄﺎﻗﺔ
ھﺮﺗﺰ
50
/
ﻓﻮﻟﺖ
240
ھﺮﺗﺰ
50
/
ﻓﻮﻟﺖ
240
ھﺮﺗﺰ
50
/
ﻓﻮﻟﺖ
240
ھﺮﺗﺰ
50
/
ﻓﻮﻟﺖ
240
ھﺮﺗﺰ
50
/
ﻓﻮﻟﺖ
240
ھﺮﺗﺰ
50
/
ﻓﻮﻟﺖ
240
ھﺮﺗﺰ
50
/
ﻧﯿﻮﺗﻦ
/ 3
ﻓﻮﻟﺖ
ھﺮﺗﺰ
50
/
ﻧﯿﻮﺗﻦ
/ 3
ﻓﻮﻟﺖ
ھﺮﺗﺰ
50
/
ﻧﯿﻮﺗﻦ
/ 3
ﻓﻮﻟﺖ
ھﺮﺗﺰ
50
/
ﻧﯿﻮﺗﻦ
/ 3
ﻓﻮﻟﺖ
ھﺮﺗﺰ
50
/
ﻧﯿﻮﺗﻦ
/ 3
ﻓﻮﻟﺖ
اﻟﻀﻮﺿﺎء دﯾﺴﯿﺒﻞ
ﻣﻠﻢ
)
اﻷﺑﻌﺎد
(
ﺻﻮﺗﻲ
)
28
31
35
م
5
م
30
م
19.0
7.4
8.2
17.5
4.9
5.7
16.0
3.4
3.9
14.0
2.8
3.1
11.5
2.3
2.5
9.5
1.8
2.0
AHWT18-32
ACC028TP
ACC020TP
ACC018TP
7200
6300
6300
24590
21520
21520
0.60
0.54
0.54
2.64
2.38
2.38
17
12
12
7
6
11
11
11
24
24
24
2
2
.
درﺟﺔ ﻣﺌﻮﯾﺔ ﻟﻠﻤﯿﺎه اﻟﺨﺎرﺟﺔ
(
ﻛﯿﻠﻮ وات
)
اﻟﻘﺪرة
إﻟﻰ
220
ﻣﻦ
1.2
إﻟﻰ
220
ﻣﻦ
2.4
إﻟﻰ
220
ﻣﻦ
2.4
إﻟﻰ
220
ﻣﻦ
3.6
إﻟﻰ
220
ﻣﻦ
2.4
إﻟﻰ
220
ﻣﻦ
3.6
415
إﻟﻰ
380
ﻣﻦ
4.8
415
إﻟﻰ
380
ﻣﻦ
7.2
415
إﻟﻰ
380
ﻣﻦ
5.4
415
إﻟﻰ
380
ﻣﻦ
7.2
415
إﻟﻰ
380
ﻣﻦ
10.8
.
ﻣﺘﻄﻠﺒﺎت اﻟﻜﺎﺑﻞ
ﯾﻠﺰم ﺗﺰوﯾﺪ ﻃﺎﻗﺔ اﻟﺴﺨﺎن اﻟﻜﮭﺮﺑﺎﺋﻲ ﺑﺸﻜﻞ ﻣﻨﻔﺼﻞ، ﻛﻤﺎ ﯾﺠﺐ أن ﯾﻠﺒﻲ ﺣﺠﻢ اﻟﺘﻘﺎﻃﻊ
.
ﯾﻌﺪ اﻟﺘﻮﺻﯿﻞ ﺑﺎﻟﻄﺮف اﻷرﺿﻲ ﺿﺮورة ﺑﺎﻟﻨﺴﺒﺔ ﻟﻠﺴﺨﺎن اﻟﻜﮭﺮﺑﺎﺋﻲ
(
ھﺮﺗﺰ
50
/
ﯿﻮﺗﻦ
ﻧ
/ 3
اﻟﺤﺪ اﻷﻗﺼﻰ
أﻗﺼﻰ ﺗﺪﻓﻖ ﻟﻠﻤﯿﺎه
) ( م
ﻟﻠﺘﻔﺮﯾﻎ
(
ﺳﺎﻋﺔ
/
ﻟﺘﺮ
)
6
8
6
10
6
18
AMDS-CP10
20
م
10
م
5
9.0
9.5
6.5
7.0
4.6
5.0
3.6
4.0
2.7
3.2
2.2
2.5
.
ﻣﻠﻢ
6
ﺗﻢ اﺣﺘﺴﺎب ارﺗﻔﺎع اﻟﺘﻔﺮﯾﻎ اﻟﻤﺤﺪد ﻓﻲ اﻟﺠﺎﻧﺐ اﻟﻌﻠﻮي ﺑﺎﺳﺘﺨﺪام أﻧﺒﻮب ﻣﺮن ﺑﻘﻄﺮ داﺧﻠﻲ ﯾﺒﻠﻎ
AHWT08-15
ACC015TP
ACC011TP
4200
3600
14340
12290
0.36
0.31
1.59
1.37
13
7
6
3
2
9.5
9.5
21
21
2
2
2
50
درﺟﺔ ﻣﺌﻮﯾﺔ ﻟﻠﻤﯿﺎه اﻟﺪاﺧﻠﺔ، و
ﻃﺮاز اﻟﺴﺨﺎن
AHDP1.2T08-15
ACC009TP/011TP/015TP
AHDP2.4T08-15
AHDP2.4T18-32
ACC018TP/020TP/028/TP/032TP
AHDP3.6T18-32
AHDP2.4T35-45
AHDP3.6T35-45
AHDP4.8T35-50
ACC035TP/045TP/050TP
AHDP7.2T35-50
AHDP5.4T60
AHDP7.2T60
AHDP10.8T60
.
ﯾﻠﺰم ﺗﺜﺒﯿﺖ اﻟﺴﺨﺎن اﻟﻜﮭﺮﺑﺎﺋﻲ ﺑﺎﻟﻮﺣﺪات اﻟﺪاﺧﻠﯿﺔ ﺑﺈﺣﻜﺎم
.
ﯾﻨﺒﻐﻲ ﺗﺤﺪﯾﺪ اﻟﻤﻨﺼﮭﺮ اﻟﻤﻨﺎﺳﺐ ﻟﻺﻗﺮان ﺑﺎﻟﺴﺨﺎن اﻟﻜﮭﺮﺑﺎﺋﻲ
ﻓﻮﻟﺖ
380
)
ھﺮﺗﺰ
50
~ /
ﻓﻮﻟﺖ
220
أﻗﺼﻰ دﺧﻞ
اﻟﻄﺎﻗﺔ
(
وات
)
ﻟﻠﻄﺎﻗﺔ
240
إﻟﻰ
10
ھﺮﺗﺰ
50
240
إﻟﻰ
18
ھﺮﺗﺰ
50
240
إﻟﻰ
18
ھﺮﺗﺰ
50
AMDS-CP08
م
30
م
20
م
10
4.3
5.3
6.3
3.2
4.1
5.0
2.5
3.0
3.8
2.0
2.2
2.6
1.5
1.8
2.0
1.0
1.2
1.4
.
ﻗﻢ ﺑﺘﺮﻛﯿﺐ ﻣﻀﺨﺔ اﻟﺘﻜﺎﺛﻒ، وﯾﻤﻜﻨﻚ اﻟﺮﺟﻮع ﻟﺪﻟﯿﻞ اﻟﺘﺮﻛﯿﺐ
103
ﻣﻠﻒ اﻟﺘﺴﺨﯿﻦ
:
اﻟﻤﻠﺤﻘﺎت
اﻟﻄﺮاز
داﺧﻠﻲ ﻣﺘﻮاﻓﻖ
ACC009TP
3600
وات
ﻗﺪرة
وﺣﺪة ﺣﺮارﯾﺔ
12290
(
ﺳﺎﻋﺔ
/
ﺑﺮﯾﻄﺎﻧﯿﺔ
ﻣﺘﺮ
0.31
ﺳﺎﻋﺔ
/
ﻣﻜﻌﺐ
ﺗﺪﻓﻖ
اﻟﻤﺎء
ﺟﺎﻟﻮن ﻟﻜﻞ
1.37
دﻗﯿﻘﺔ
اﻧﺨﻔﺎض ﺿﻐﻂ اﻟﮭﻮاء
7
(
ﺑﺎﺳﻜﺎل
)
اﻧﺨﻔﺎض ﺿﻐﻂ اﻟﻤﯿﺎه
2
(
ﻛﯿﻠﻮ ﺑﺎﺳﻜﺎل
)
9.5
ﻛﺠﻢ
ﺻﺎﻓﻲ
اﻟﻮزن
21
رﻃﻞ
2
اﻟﺼﻔﻮف
60
:
ﺣﺎﻟﺔ اﻻﺧﺘﺒﺎر
ﻓﻲ
:
ﻣﻠﺤﻮﻇﺔ
اﻟﺴﺨﺎن اﻟﻜﮭﺮﺑﺎﺋﻲ
:
اﻟﻤﻠﺤﻘﺎت
ﻃﺮاز اﻟﻮﺣﺪة اﻟﺪاﺧﻠﯿﺔ
ACC035TP/045TP
ACC060TP
1.
:
ﻣﻼﺣﻈﺎت
2.
3.
4.
:
اﺧﺘﺒﺎر اﻟﺘﺰوﯾﺪ ﺑﺎﻟﻄﺎﻗﺔ
5.
ﻣﻀﺨﺔ اﻟﺘﻜﺎﺛﻒ
:
اﻟﻤﻠﺤﻘﺎت
اﻟﻄﺮاز
220
ﻣﻦ
AMDS-CP08
/
ﻓﻮﻟﺖ
220
ﻣﻦ
AMDS-CP10
/
ﻓﻮﻟﺖ
220
ﻣﻦ
AMDS-CP20
/
ﻓﻮﻟﺖ
اﻟﻄﺮاز
L
م
5
H
6.8
م
1
5.5
م
2
4.2
م
3
3.0
م
4
2.2
م
5
1.5
م
6
1 .
:
ﻣﻼﺣﻈﺎت
2.