Roth Basicline T Installationshandbuch Seite 90

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation - Device Parameters
DX
FUNCTION
D01
Heating
Control
D02
Room
Temperature
Offset
D03
Sensor probe or
Cylinder thermostat
connection
D04
Sensor probe
used as air sensor
or floor sensor
D05
Cooling Control
D06
Actuator type
D07
Valve protection
90
Installer Manual
SYSTEM SETTING
0
Pulse Width Modulation
1
On-Off 0.5 Deg C +/- 0.25 Deg C
2
On-Off 1.0 Deg C +/- 0.5 Deg C
-3.0 to 3.0
Temperature Offset from
Deg C
Measured Temperature to
Compensate for any error
0
Sensor stat not Connected
1
0
D03 must be set to 1 then
external sensor be used as
Air sensor. There will be no
internal temp measurement
1
D03 must be set to 1 then
external sensor used for floor
protection. Internal temp is
1
On-Off 0.5 Deg C +/- 0.25 Deg C
2
On-Off 1.0 Deg C +/- 0.5 Deg C
0
1
0
1
DEFINITION
Sensor stat Connected
measured by stat
NO Normally Open
NC Normally Closed
Disable
Enable
DEFAULT
0
0 Deg C
0
0
2
1
1