7.3.4 Scan, repeat function, and random play
1. By pressing the button 2 INT the first ten seconds of each title of the CD are successively played
(indication SCAN ON). To return to normal play press the button 2 INT again (indication SCAN OFF).
2. With the button 3 RPT you can activate continuous repeat of the selected title (indication RPT ON). To
return to normal play press the button 3 RPT again (indication RPT OFF).
3. With the button 4 RDM you can activate random play (indication SHF ON). The titles are now played in
random order. To return to normal play press the button 4 RDM again (indication SHF OFF).

8. CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents! There are no serviceable parts inside the device except for the fuse. Maintenance and
service operations are only to be carried out by authorized dealers.

8.1 Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. Before
replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuse holder with a fitting screwdriver from the housing (anti-clockwise).
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing and fix it.
Should you need any spare parts, please use genuine parts. If the power supply cable of this device
becomes damaged, it has to be replaced by authorized dealers only in order to avoid hazards. Should you
have further questions, please contact your dealer.

9. TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Output power:
Output type:
Outputs:
Inputs:
Frequency range:
S/N ratio:
Distortion:
Slew rate:
Tuner channel:
Step pace:
Dimensions:
Weight:
Please note: Every information is subject to change without prior notice. 12.10.2009 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
115/230 V AC, 50/60 Hz ~ or 12 V emergency power battery
150 W
50 W RMS
25 V, 50 V, 70 V, 100 V or 4 Ω
screw connectors
2 x mic -50 dB, 600 Ω (6.3 mm jack, unbal.)
1 x aux/mic -20 dB, 10 kΩ/-50 dB, 600 Ω (6.3 mm jack, unbal.)
80 Hz - 15 kHz
105 dB
<0.6 %
70 V/ms
FM 87 - 108 Hz
AM 522 - 1.161 Hz
FM 50 kHz
AM 9 kHz
483 x 320 x 100 mm
9 kg
28/28