Operating Instructions
TR4
4
Mounting
WARNING
Note
8014467/YTD7/2016-03-30
Subject to change without notice
Mounting
Mounting is only allowed to be performed by authorized specialist
personnel!
Mounting must be undertaken in accordance with the following notes
and the stated specifications and is to be undertaken by appropriately
qualified persons.
Follow the following mounting instructions. Otherwise the warranty will
be rendered void.
This device is part of a protective device for the protection of a ma-
chine. Prior to mounting a risk analysis should be undertaken to deter-
mine whether this device's specifications are suitable for all foresee-
able operating and environmental parameters at the machine in which
it is to be installed.
Steps for mounting the device
= Select mounting position for the safety switch such that the sensor
and actuator are easily accessible for inspection and replacement,
and are protected against damage.
= Ensure that a hazard is also excluded if the actuator has yet not
reached the safe switch-off distance on opening the guard.
= Pay attention to EN ISO 14 119 on mounting the safety switch and
the actuator.
= Pay attention to EN ISO 14 119 on reducing possible ways of
bypassing an interlocking device.
= Mount the actuator on the moveable part of the guard.
= Mount the sensor on the fixed part of the guard.
= Align the sensor and actuator in relation to each other such that their
front faces are within the switch-on distance of 15 mm or less apart
when the guard is closed (see Fig. 1).