Description
Status BW: 1x short = status display; hold for 3 seconds =
manual start for the backwash/rinse cycle
3.3.6

Audio signal

Each touch of a key is acknowledged with an acoustic "beep"
signal. Further audio signal sequences represent certain
conditions, warnings or alarms. If necessary, the audio signal can
be turned off completely.
Audio signal
2x short
5x short
3.3.7

Additional relay output contacts

Various functions can be performed with two additional relay
outputs. Both relay outputs are potential-free.
Relay output Z1, Z2
The contact Z1, Z2 is provided for other devices. If the contact Z1,
Z2 is closed, the external device acknowledges that the BADU
OmniTronic has reached its position and that the pump can be
turned on. In the menu structure "Relay 5", the parameter can be
specified individually.
Factory settings:
Contact Z1, Z2 closes, when one of four positions is reached.
Relay output 11, 14, 12
This output switches as soon as the level detector in the pool
registers too little water. This signal could be used for a magnetic
valve to feed water.
3.3.8

Digital inputs

The digital inputs can be used as follows:
DI1 and DI2 potential-free contacts only:
DI1: for potential-free contacts, for example pressure switches
Function: When the pressure switch (t>3s) is triggered, a
backwash/rinse cycle is started (available optionally; article no.
260.6402.087)
DI2: for potential-free contacts, for example manual, external
switches
Function: The pump switches to the "Filter" position as soon as
the switch is closed.
20 EN