4. Technical data

Order Type
Supply voltage
Battery life
Temperature setting range
Temperature resolution
Switching current
Output
Output signal
Ambient temperature
Pollution degree
Rated impulse voltage
Ball pressure test temperature
Voltage and Current
for the for purposes of
interferncemeasurements
Safety class
Degree of protection
Software class
Weight (with batteries)
Energy class
(acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
E100
2 x AA 1,5V alkaline batteries
3 years (typically)
5 °C to 30 °C
0,5 °C (for setting and display)
max. 8(2)A AC; 24 ... 230 V~
Relay change over contact, voltage free
PID with PWM (pulse width modulation) or
ON/OFF selectable
Operating
0 °C to 40 °C not condensing
Storage
–20 °C to 85 °C not condensing
2
4 kV
75 ± 2 °C
230 V, 0,1A
II (see Caution, page 28)
IP 30
A
~ 300 g
IV = 2 %