Installation instructions, only for experts
the sauna heater off when objects, e.g. a towel, are placed on the sauna heater.
To install the safety shut-off device, perform the following steps:
1. Install the safety shut-off device in accordance with the operating instruc-
tions for the device.
2. Guide the wires for the safety shut-off device through the cable bushing
into the low-voltage connection area
3. Connect the wires for the temperature sensor to the terminals labelled "OSG"
in terminal strip

5.11. Remote start

!
The remote start function is deactivated ex-works. When the remote
start function is activated when starting up the unit for the first time,
the sauna control unit may only be used for operating and regulating
a sauna heater which has been certified as satisfying the combustion
test described in paragraph 19.101 of EN 60335-2-53. Alternatively, the
corresponding safety shut-off device may be installed in, or above, the
sauna heater. Activation must be carried out by an electrician (see 8.4.
Activating/deactivating the remote start function on page 28).
This is connected using terminals "S", "B" and "C". "S" stands for sauna mode.
"B" is a +24 V DC output. This must be activated using a switch or an actuator
on terminal "S".

5.12. Status output

Any electrical device can be connected to the status output terminal which is
suitable for 24 V DC voltage and draws a current no greater than 200 mA.
Make sure the polarity is correct when connecting a device. When LEDs are
used, a suitable series resistor must be used.