Herunterladen Inhalt Inhalt Diese Seite drucken

Nice Spin10KCE Anweisungen Und Hinweise Seite 19

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 92
Table 18a: To modify the adjustable parameters in "standard programming" mode
1.
Press and hold [Set] for approx. 3s
2.
Release the key [Set] when led L1 starts to flash
3.
Press key [
] to move the flashing led to the "input led" associated with the parameter to be
modified
4.
Press and hold [Set] during steps 5 and 6
5.
Wait approx. 3s after which the led associated with the current level of the parameter to be modified
will light up
6.
Press key [
] to move the led associated with the parameter value.
7.
Release [Set]
8.
Wait 10s to exit the programming mode automatically after the maximum time interval.
Note: Points 3 to 7 can be repeated during the same programming phase to modify other parameters
7.2.5) LEVEL 1 programming examples (ON-OFF functions)
This example shows the sequence of operations required to change the factory setting of the functions to deactivate the function of "Vari-
able Sensitivity" (L1) and activate "Short Partial Open" (L3).
Table 19: Example of LEVEL 1 programming in "Programming on power-up" mode
1.
Switch off SPIN (for example by removing fuse F1)
2.
Press and hold [Set]
3.
Switch on SPIN (for example by inserting fuse F1)
4.
Wait for the flashing signal indicating control unit start-up and keep [Set] pressed until L1 starts to flash
(approx. 6s)
5.
Release [Set]
6.
Press [Set] once to change the status of the function associated with L1 (Variable Sensitivity) led L1
now emits long flashes
7.
Press [
] twice to move the flashing led onto led L3
8.
Press [Set] once to change the status of the function associated with L3 (Partial open) led L3 now
emits long flashes
9.
Wait 10s to exit the programming mode automatically after the maximum time interval
On standby to exit programming mode, leds L1 and L3 must remain lit to indicate that the functions "Variable Sensitivity disabled" and "Short
Partial Open" are active.
This example shows the sequence of operations required to change the factory setting of the functions to activate the functions of "High
opening speed" (L2) and "Automatic Closure" (L3).
Table 19a: Example of LEVEL 1 programming in "Standard programming" mode
1.
Press and hold [Set] for approx. 3s
2.
Release the key [Set] when led L1 starts to flash
3.
Press the key [
] once to move the flashing led onto led L2
4.
Press [Set] once to change the status of the function associated with L2 (Opening speed) led L2 now
emits long flashes
5.
Press the key [
] once to move the flashing led onto led L3
6.
Press [Set] once to change the status of the function associated with L3 (Automatic closure) led L3
now emits long flashes
7.
Wait 10s to exit the programming mode automatically after the maximum time interval
At the end of these operations leds L2 and L3 must remain lit to indicate that the functions "High opening speed" and "Automatic closure" are
enabled.
Example
GB
3s
SET
L1
SET
SET
SET
10s
Example
L1
SET
L1
SET
6s
SET
L1
SET
L3
SET
L3
10s
Example
SET
3s
L1
SET
L2
L2
SET
L3
SET
L3
10s
19

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Spin11kce

Inhaltsverzeichnis