Installation
The sauna oven is intended only for a supply
voltage of 400 V 3 N AC.
drawing shows optional equipment
The sauna heater must be operated with a suita-
ble sauna control unit with an additional power
extension unit. (see Technical Data)
Leakage current: max. 0.75 mA per kW heating
capacity
Intended use: sauna heater for use in domestic
and commercial saunas.
28
Minimum clearances
The minimum height of the sauna cabin must
be 210 cm on the inside.
During the installation of the sauna oven, make
certain that the vertical clearance from the upper
edge of the sauna oven to the sauna ceiling is
at least 130 cm, and that the horizontal (lateral)
clearance between the oven and the cabin wall
or other flammable materials is at least 10 cm.
Minimum clearances listed in the following
drawings Fig.1 and Fig. 1b must be observed!
Maße in mm
Maße in mm
Heater guard rail
EN
all dimensions in mm
Fig. 1
Air supply by installat-
Zuluft bei Montage
tion in the
in der Mitte der Kabine
über Zuluftkanal
middle of the sauna
ggf. mit Lüfter
through an air channel,
Zuluft bei Montage
if necessary mechanical
in der Mitte der Kabine
über Zuluftkanal
ventilation
ggf. mit Lüfter