The RP1/RP2 probe must be installed by a competent person observing relevant safety precautions.
Before commencing work, ensure the machine tool is in a safe condition with the power switched OFF
Connection is made to the RP2 via a 2-way female connector (supplied). This is available as a
Renishaw spare part, or sourced directly from Harwin Connectors.
Female connector
Renishaw
or
Harwin
The following tools are required to assemble the wires
and crimp sockets into the female connector:
Crimp tool
Used to crimp wire in crimp socket.
Renishaw
or
Harwin
Crimp tool setting :
Positioner
Used to locate crimp socket in crimp tool.
Renishaw
or
Harwin
Insertion/removal tool
Used to insert/remove crimp socket in/from the
connector shell.
Renishaw
or
Harwin
Wire sizes:
(Supplied by user)
RP2/RP2 DD CONNECTION ASSEMBLY
and the power supply to the MI 8 disconnected.
Part No.
P-CN23-020A
M80-8980205
Part No.
P-TL04-0005
M22520/2-01
6
Part No.
P-TL04-0006
T5747
Part No.
P-TL04-0007
T5748-19
26 (AWG) 19 x 0.1
24 (AWG) 7 x 0.2
SAFETY
2-way
female socket
Wire stripping
➛ ➛ ➛ ➛ ➛
Plug
Rear view of
RP2 probe
Ø 1.1 mm max.
2.0 mm nominal
1-7