Error Codes

Number
Indoor EEPROM (Electrically Erasable Programmable
1
Read-Only Memory) error
2
Indoor and outdoor unit communication malfunction
3
Indoor fan speed malfunction
4
Indoor room temperature sensor error
5
Evaporator coil temperature sensor error
6
Refrigerant leak detection system malfunction
7
Water level alarm malfunction
Dual indoor unit (twin model only) communication
8
malfunction
9
Other twin model malfunction
10
Overload protection
11
Outdoor temperature sensor error
12
Outdoor condenser pipe sensor error
13
Discharge air temperature sensor error
Outdoor EEPROM (Electrically Erasable Programma-
14
ble Read-Only Memory) error
15
Outdoor fan speed (DC fan motor only) malfunction
16
Inverter module IPM protection
17
High/Low voltage protection
18
Compressor top overheating protection
19
Outdoor low temperature protection
20
Compressor drive error
21
Mode conflict
22
Compressor low-pressure protection
23
Outdoor IGBT sensor error
Cause
The number
Timer
of flashes
indicator
per second
1
Off
2
Off
4
Off
5
Off
6
Off
7
Off
8
Off
9
Off
10
Off
1
On
2
On
3
On
4
On
5
On
6
On
1
Flash
2
Flash
3
Flash
4
Flash
5
Flash
6
Flash
7
Flash
8
Flash
MANUAL
Error Code
E0
E1
E3
E4
E5
EC
EE
E8
E9
F0
F1
F2
F3
F4
F5
P0
P1
P2
P3
P4
P5
P6
P7